Error Code
Message Information
PSU0006
Message
Power supply <
number
> type mismatch.
LCD Message
Power supply <
number
> is incorrectly configured. Check PSU.
Details
Power supplies should be of the same input type and power rating.
Action
Install matched power supplies and review proper configuration in
this manual.
PSU0016
Message
Power supply <
number
> is absent.
LCD Message
PSU <
number
> is absent. Check PSU.
Details
The power supply has been removed or has failed.
Action
1.
Remove and reinstall the power supply.
2.
Check cables and subsystem components in the system for
damage.
3.
If the issue persists, see
Getting Help
.
PSU0031
Message
Cannot communicate with power supply <
number
>.
LCD Message
Cannot communicate with PSU <
number
>. Re-seat PSU.
Details
The power supply may operate, however power supply monitoring is
degraded. System performance may be degraded.
Action
Remove and reinstall the power supply. If the issue persists, see
Getting Help
.
PSU0032
Message
The temperature for power supply <
number
> is in a warning range.
Details
System performance may be degraded.
Action
Check the system operating environment, including airflow and inlet
temperature. Check system logs for temperature and thermal
component failures.
PSU0033
Message
The temperature for power supply <
number
> is outside of the
allowable range.
LCD Message
PSU <
number
> temperature outside of range. Check PSU.
Details
System performance may be degraded.
Action
Check the system operating environment, including airflow and inlet
temperature. Check system logs for temperature and thermal
component failures.
159
Содержание PowerEdge T420
Страница 1: ...Dell PowerEdge T420 Systems Owner s Manual Regulatory Model E20S Series Regulatory Type E20S001 ...
Страница 8: ...Diagnostic Messages 165 Alert Messages 165 10 Getting Help 167 Contacting Dell 167 ...
Страница 40: ...40 ...
Страница 126: ...126 ...
Страница 136: ...136 ...
Страница 148: ...148 ...
Страница 166: ...166 ...