Error Code
Message Information
Action
Review the technical specifications for supported processor types.
CPU0010
Message
CPU <
number
> is throttled.
Details
The CPU is throttled due to thermal or power conditions.
Action
Review system logs for power or thermal exceptions.
CPU0023
Message
CPU <
number
> is absent.
LCD Message
CPU <
number
> is absent. Check CPU.
Action
Verify processor installation. If present, re-seat the processor.
CPU0204
Message
CPU <
number
> <
name
> voltage is outside of range.
LCD Message
CPU <
number
> <
name
> voltage is outside of range. Re-seat CPU.
Details
Voltages outside the allowable range may damage electrical
components or may cause the system to shutdown.
Action
1. Turn off the system and remove input power for one minute.
2. Ensure the processor is seated correctly.
3. Reapply input power and turn on the system.
4. If the issue persists, see
Getting Help
.
CPU0700
Message
CPU <
number
> initialization error detected.
LCD Message
CPU <
number
> initialization error detected. Power cycle system.
Details
System BIOS was unable to initialize the processor.
Action
1. Turn off the system and remove input power for one minute.
2. Ensure the processor is seated correctly.
3. Reapply input power and turn on the system.
4. If the issue persists, see
Getting Help
.
CPU0701
Message
CPU <
number
> protocol error detected.
LCD Message
CPU <
number
> protocol error detected. Power cycle system.
Details
System event log and operating system logs may indicate that the
exception is external to the processor.
Action
1. Check system and operating system logs for exceptions. If no
exceptions are found, continue.
150