![Dell PowerEdge R420xr Скачать руководство пользователя страница 122](http://html.mh-extra.com/html/dell/poweredge-r420xr/poweredge-r420xr_owners-manual_85444122.webp)
Error Code
Message Information
Action
Check the system operating environment, including airflow
and inlet temperature. Check system logs for temperature
and thermal component failures.
PSU0034
Message
An under voltage fault detected on power supply <
number
>.
LCD Message
An under voltage fault detected on PSU <
number
>. Check
power source.
Details
This failure may be the result of an electrical issue with
cables or subsystem components in the system.
Action
1.
Remove and reinstall the power supply.
2.
Check cables and subsystem components in the system
for damage.
3.
If the issue persists, see
Getting Help
.
PSU0035
Message
An over voltage fault detected on power supply <
number
>.
LCD Message
Over voltage fault on PSU <
number
>. Check PSU.
Action
Check input power or reinstall the power supply. If the issue
persists, see
Getting Help
.
PSU0036
Message
An over current fault detected on power supply <
number
>.
LCD Message
An over current fault detected on PSU <
number
>. Check
PSU.
Details
This failure may be the result of an electrical issue with
cables or subsystem components in the system.
Action
1.
Remove and reinstall the power supply.
2.
Check cables and subsystem components in the system
for damage.
3.
If the issue persists, see
Getting Help
.
PSU0037
Message
Fan failure detected on power supply <
number
>.
LCD Message
Fan failure detected on PSU <
number
>. Check PSU.
Action
Check for fan blockage. If the problem persists, see
Getting
Help
.
PSU0076
Message
A power supply wattage mismatch is detected; power supply
<
number
> is rated for <
value
> watts.
122