Error Code
Message Information
5. If the issue persists, see
Getting Help
.
FAN0000
Message
Fan <
number
> RPM is less than the lower warning threshold.
Details
Fan operating speed is out of range.
Action
Remove and reinstall the fan. If the issue persists, see
Getting Help
.
FAN0001
Message
Fan <
number
> RPM is less than the lower critical threshold.
LCD Message
Fan <
number
> RPM is outside of range. Check fan.
Details
Fan operating speed is out of range.
Action
Remove and reinstall the fan. If the issue persists, see
Getting Help
.
FAN1201
Message
Fan redundancy is lost.
LCD Message
Fan redundancy is lost. Check fans.
Details
Fan has failed.
Action
Remove and reinstall failed fans or install additional fans.
HWC1001
Message
The <
name
> is absent.
LCD Message
The <
name
> is absent. Check hardware.
Details
The absent device may be necessary for proper operation. System
functionality may be degraded.
Action
Reinstall or reconnect the hardware.
HWC2003
Message
The storage <
name
> cable is not connected, or is improperly
connected.
LCD Message
Storage <
name
> cable or interconnect failure. Check connection.
Details
The cable may be necessary for proper operation. System
functionality may be degraded.
Action
Check if the cable is present, then reinstall or reconnect.
HWC2005
Message
The system board <
name
> cable is not connected, or is improperly
connected.
LCD Message
System board <
name
> cable connection failure. Check connection.
Details
The cable may be necessary for proper operation. System
functionality may be degraded.
130
Содержание PowerEdge R320
Страница 1: ...Dell PowerEdge R320 Systems Owner s Manual Regulatory Model E18S Series Regulatory Type E18S001 ...
Страница 8: ...8 ...
Страница 36: ...36 ...
Страница 118: ...118 ...
Страница 124: ...124 ...
Страница 142: ...142 ...