background image

8

Getting Started With Your System

Installing PowerConnect MPS600 or MPS1000 in a Rack

The PowerConnect MPS600 or MPS1000 can be installed in most standard 
19-inch racks.

 

NOTE: 

For racks that are not pre-threaded, cage nuts are provided.

Figure 1-6.

Attaching Mounting Brackets–PowerConnect MPS600 or MPS1000 

3

Use the screws that are provided to attach a mounting bracket to each side 
of the 

PowerConnect 

MPS600 or MPS1000.

4

Position the 

PowerConnect 

MPS600 or MPS1000 in the rack and align the 

holes in the mounting bracket with the holes in the rack.

5

Insert and tighten two screws through each of the mounting brackets.

Содержание PowerConnect MPS 1U Shelf

Страница 1: ...Dell PowerConnect RPS720 MPS600 MPS1000 and MPS 1U Shelf Getting Started With Your System Regulatory Model PowerConnect RPS720 MPS600 and MPS1000 ...

Страница 2: ...Inc All rights reserved Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc is strictly forbidden Trademarks used in this text Dell the DELL logo and PowerConnect are trademarks of Dell Inc EMC is a registered trademark of EMC Corporation Other trademarks and trade names may be used in this publication to refer to either the entities claiming the mar...

Страница 3: ...vidual power supplies 1U 19 inch rack mountable system NOTE The PowerConnect RPS720 redundant power bank provides four external redundant power supplies for your PowerConnect switches eliminating the power supply as a single point of failure Dell PowerConnect MPS600 Figure 1 2 Front Panel Indicators PowerConnect MPS600 Supports one PowerConnect 55xxP PoE switch through 48 V DC output Dedicated 600...

Страница 4: ...ted switch Front panel LEDs display status of the power supply 1U 19 inch rack mountable system with brackets Up to three MPS1000 units in a MPS 1U Shelf density 3 per 1U 19 inch rack Unpacking Package Contents Before you install the RPS720 MPS600 MPS1000 or MPS 1U Shelf verify your package contents for One of the following units RPS720 Redundant power bank supports up to four switches MPS600 Modu...

Страница 5: ...er bank or the MPS600 MPS1000 external power supply PowerConnect RPS720 Installing PowerConnect RPS720 on a Flat Surface You can install the PowerConnect RPS720 on any appropriate level surface that can safely support the weight of the switches the PowerConnect RPS720 and their attached cables There must be adequate space around the PowerConnect RPS720 for ventilation and to access cable connector...

Страница 6: ...threaded cage nuts are provided Figure 1 4 Attaching Mounting Brackets PowerConnect RPS720 3 Use the screws that are provided to attach a mounting bracket to each side of the PowerConnect RPS720 4 Position the PowerConnect RPS720 in the rack and align the holes in the mounting bracket with the holes in the rack 5 Insert and tighten two screws through each of the mounting brackets ...

Страница 7: ...PowerConnect RPS720 PowerConnect MPS600 or MPS1000 Installing PowerConnect MPS600 or MPS1000 on a Flat Surface You can install the PowerConnect MPS600 or MPS1000 on any appropriate level surface that can safely support the weight of the switch the PowerConnect MPS600 or MPS1000 and their attached cables There must be adequate space around the PowerConnect MPS600 or MPS1000 for ventilation and to a...

Страница 8: ...ed cage nuts are provided Figure 1 6 Attaching Mounting Brackets PowerConnect MPS600 or MPS1000 3 Use the screws that are provided to attach a mounting bracket to each side of the PowerConnect MPS600 or MPS1000 4 Position the PowerConnect MPS600 or MPS1000 in the rack and align the holes in the mounting bracket with the holes in the rack 5 Insert and tighten two screws through each of the mounting...

Страница 9: ...switch and the MPS600 or MPS1000 PowerConnect MPS 1U Shelf Installing PowerConnect MPS 1U Shelf on a Flat Surface You can install the PowerConnect MPS 1U Shelf on any appropriate level surface that can safely support the weight of up to three switches up to three PowerConnect MPS600 or MPS1000 and their attached cables There must be adequate space around the PowerConnect MPS 1U Shelf for ventilati...

Страница 10: ...t MPS600 or MPS1000 in the MPS 1U Shelf After Installation 1 Install up to three PowerConnect MPS600 or MPS1000 or combinations into the MPS 1U Shelf Figure 1 8 Back View PowerConnect MPS 1U Shelf 2 Plug one end of the switch DC power cord 16 pin into the connector labeled MPS on the back of an available switch Connect the other end of the switch DC power cord to the DC OUT connector on the back o...

Страница 11: ...oubleshoot the system and install or replace system components These documents are available online at support dell com manuals NOTE Always check for updates on support dell com manuals and read the updates first because they often supersede information in other documents Obtaining Technical Assistance If you need help with a technical problem see the Dell Support website at support dell com for t...

Страница 12: ... Input Frequency Range 47 to 63 Hz Max Input AC Current 2 3 A max per supply 9 2 A total for four supplies in PowerConnect RPS720 Output Voltage and Current Parameter 12 V output unit Nominal Output Voltage 12 V Absolute Maximum Tolerance 5 Output Ripple Voltage 500 mV pk pk Minimum Current 0 0 A Maximum Current 15 A DC FAN Specification Bearing Type Two ball bearing Rated Voltage 12 V DC Operatin...

Страница 13: ...64 VAC and a 12 VDC regulated output This regulated output supplies power to other power supply backup source The power supply incorporates over current protection and OVP Input Voltage Universal input 90 to 264 VAC Input Frequency Range 47 to 63 Hz single phase AC Max Input AC Current 8 0 A maximum Output Voltage and Current No of Output 1 Nominal Output Voltage Set Point 48 V DC Set Point Tolera...

Страница 14: ... AC Max Input AC Current 12 0 A maximum Output Voltage and Current No of Output 1 Nominal Output Voltage Set Point 48 V DC Set Point Tolerance 1 Total Error Band 2 Minimum Current 1 0 A Maximum Current 18 52 A Physical Height 44 mm 1 73 in maximum Width 440 mm 17 32 in maximum Depth 402 mm 15 83 in maximum Environmental Considerations NOTE For additional information about environmental measurement...

Отзывы: