![Dell PowerConnect M6220 Скачать руководство пользователя страница 151](http://html.mh-extra.com/html/dell/powerconnect-m6220/powerconnect-m6220_user-configuration-manual_84547151.webp)
Managing a Switch Stack
151
• If the unit number is configured and there are no other devices using the
unit number, then the switch starts using the configured unit number.
• If the switch detects that the maximum number of units already exist in
the stack making it unable to assign a unit number, then the switch sets its
unit number to
unassigned
and does not participate in the stack.
Adding a Switch to the Stack
When adding a new member to a stack, make sure that only the stack cables,
and no network cables, are connected before powering up the new unit. Stack
port configuration is stored on the member units. If stacking over Ethernet
ports, configure the ports on the unit to be added to the stack as stacking
ports and power the unit off prior to connecting the stacking cables. Make
sure the links are not already connected to any ports of that unit. This is
important because if STP is enabled and any links are UP, the STP re-
convergence will take place as soon as the link is detected.
After the stack cables on the new member are connected to the stack, you can
power up the new units, beginning with the unit directly attached to the
currently powered-up unit. Always power up new stack units closest to an
existing powered unit first. Do not connect a new member to the stack after it
is powered up. Also, do not connect two functional, powered-up stacks
together. Hot insertion of units into a stack is not supported.
If a new switch is added to a stack of switches that are powered and running
and already have an elected stack master, the newly added switch becomes a
stack member rather than the stack master. In this situation, the firmware of
the new unit may be overwritten based on the configuration of the stack
master. The running configuration of the newly added unit is overwritten
with the stack master configuration. Stack port configuration is always stored
on the local unit and may be updated with preconfiguration information from
the stack master when the unit joins the stack.
You can preconfigure information about a stack member and its ports before
you add it to the stack. The preconfiguration takes place on the stack master.
If there is saved configuration information on the stack master for the newly
added unit, the stack master applies the configuration to the new unit;
otherwise, the stack master applies the default configuration to the new unit.
Содержание PowerConnect M6220
Страница 52: ...52 Introduction ...
Страница 86: ...86 Switch Features ...
Страница 100: ...100 Hardware Overview ...
Страница 116: ...116 Using the Command Line Interface ...
Страница 121: ...Default Settings 121 ...
Страница 122: ...122 Default Settings ...
Страница 142: ...142 Setting Basic Network Information ...
Страница 206: ...206 Configuring Authentication Authorization and Accounting ...
Страница 292: ...292 Managing General System Settings Figure 11 31 Verify MOTD ...
Страница 296: ...296 Managing General System Settings ...
Страница 332: ...332 Configuring SNMP ...
Страница 408: ...408 Monitoring Switch Traffic ...
Страница 560: ...560 Configuring Access Control Lists ...
Страница 582: ...582 Configuring VLANs Figure 21 6 Add Ports to VLAN 4 Click Apply 5 Verify that the ports have been added to the VLAN ...
Страница 591: ...Configuring VLANs 591 Figure 21 17 GVRP Port Parameters Table ...
Страница 597: ...Configuring VLANs 597 Figure 21 24 Double VLAN Port Parameter Table ...
Страница 693: ...Configuring Port Based Traffic Control 693 Figure 24 3 Storm Control 5 Click Apply ...
Страница 780: ...780 Configuring Connectivity Fault Management ...
Страница 804: ...804 Snooping and Inspecting Traffic Figure 27 17 DAI Interface Configuration Summary ...
Страница 818: ...818 Snooping and Inspecting Traffic ...
Страница 836: ...836 Configuring Link Aggregation ...
Страница 860: ...860 Configuring Data Center Bridging Features ...
Страница 906: ...906 Configuring DHCP Server Settings ...
Страница 940: ...940 Configuring L2 and L3 Relay Features Figure 34 3 DHCP Relay Interface Summary ...
Страница 1080: ...1080 Configuring VRRP ...
Страница 1104: ...1104 Configuring IPv6 Routing ...
Страница 1124: ...1124 Configuring DHCPv6 Server and Relay Settings Relay Interface Number Vl100 Relay Remote ID Option Flags ...
Страница 1131: ...Configuring Differentiated Services 1131 Figure 40 5 DiffServ Class Criteria ...
Страница 1158: ...1158 Configuring Class of Service Figure 41 1 Mapping Table Configuration CoS 802 1P ...
Страница 1174: ...1174 Configuring Auto VoIP Figure 42 2 Auto VoIP Interface Configuration ...
Страница 1240: ...1240 Managing IPv4 and IPv6 Multicast Figure 43 51 DVMRP Next Hop Summary ...
Страница 1266: ...1266 Managing IPv4 and IPv6 Multicast ...
Страница 1274: ...1274 System Process Definitions ...
Страница 1294: ...1294 Index ...