5-20
Dell OptiPlex Gn and Gn+ Systems Service Manual
Microprocessor/Heat Sink Assembly
Figure 5-21. Microprocessor Securing-Clip Removal
To remove the microprocessor/heat sink assembly, follow these steps:
1. Unlatch and rotate the power supply to the right (see Figure 5-14).
2. Remove the microprocessor securing clip from the microprocessor/heat
sink assembly (see Figure 5-21).
Press down on the folded part of the clip with a small screwdriver to release
the clip.
3. Push outward and then upward on the microprocessor-socket release
lever to rotate the lever to its fully vertical position (see Figure 5-22).
4. Lift the microprocessor/heat sink assembly out of its socket.
WARNING: The microprocessor chip can get extremely hot during
system operations. Be sure the chip has had sufficient time to cool
before touching it.
microprocessor
securing clip
(hooks over tabs
on the socket)
heat sink
microprocessor socket
front of computer
press here
to release
securing clip
microprocessor-socket
release lever