State
State Name
Blinking Amber Pattern
Problem Description
Suggested Resolution
If none of the memory
failed, replace the
motherboard.
S7
USB
3 blinks > short pause >
4 blinks > long pause >
repeats
Storage Subsystem
failure
Possible storage device
configuration in progress
or storage subsystem
failure.
If customer can assist to
troubleshoot, narrow
down the issue by
removing one by one
storages on motherboard
to determine which one
failed.
If identified the storage
failed, replace the
storage.
If identified the storage
failed, replace the
storage.
S8
MEM
3 blinks > short pause >
5 blinks > long pause >
repeats
Memory configuration or
incompatible error
Memory subsystem
configuration activity is in
progress. No memory
modules were detected.
If customer can assist to
troubleshoot, narrow
down the issue by
removing one by one the
memory on motherboard
to determine which one
failed. Also, combining
the configuration to
validate appropriate
combination.
If identified the
component failed, replace
the component.
If none of the component
failed, replace the
motherboard.
S9
MBF
3 blinks > short pause >
6 blinks > long pause >
repeats
System board failure
Fatal system board failure
detected.
If customer can assist to
troubleshoot, narrow
down the issue by
removing one by one the
component on
motherboard to
determine which one
failed.
Troubleshooting
77
Содержание OptiPlex 5055 Tower
Страница 1: ...Dell OptiPlex 5055 Tower Owner s Manual Regulatory Model D18M Regulatory Type D18M004 ...
Страница 12: ...4 Lift the front bezel to remove it from the computer 12 Disassembly and reassembly ...
Страница 16: ...d Press the blue tab 1 and pull the hard drive assembly out of the computer 2 16 Disassembly and reassembly ...
Страница 21: ...c Press the blue release tab 1 and slide the optical drive out of the computer 2 Disassembly and reassembly 21 ...
Страница 44: ...b Slide and lift the system board away from the computer 2 44 Disassembly and reassembly ...
Страница 80: ...Troubleshooting 8 80 Troubleshooting ...