52
Dell EMC Networking with Isilon Front-End Deployment and Best Practices Guide | version 1.0
Server/Isilon Node
Switch
Leaf interface
Server 03
Leaf 3
tengigabitethernet
1/1/17
Leaf 4
tengigabitethernet
1/1/17
Server 04
Leaf 3
tengigabitethernet
1/1/19
Leaf 4
tengigabitethernet
1/1/19
First, set the hostname, configure the OOB management interface and default gateway. Next, enable LLDP
as well as RSTP. In OS10EE, LLDP is enabled by default, in OS9, it must be enabled.
S4048-ON Leaf 3
S4048-ON Leaf 4
configure terminal
hostname S4048-Leaf3
interface management 1/1
ip address 100.67.171.15/24
no shutdown
management route 0.0.0.0/0 100.67.171.254
protocol lldp
advertise management-tlv management-
address system-description system-name
advertise interface-port-desc
protocol spanning-tree rstp
no disable
configure terminal
hostname S4048-Leaf4
interface management 1/1
ip address 100.67.171.15/24
no shutdown
management route 0.0.0.0/0 100.67.171.254
protocol lldp
advertise management-tlv management-
address system-description system-name
advertise interface-port-desc
protocol spanning-tree rstp
no disable
Configure the VLT interconnect between S4048-Leaf3 and S4048-Leaf4. Create a static port channel and
add the two VLTi connections to port channel 128. Configure the VLT domain using the management
interface of the peer switch as the backup destination. The backup destination is only utilized for the VLT
heartbeat. The
unit-id #
command will designate the primary VLT member. Once VLT is enabled, it will
dynamically change the MTU settings for the VLTi to a value of 9216.
Isilon’s OneFS supports and
recommends the use of jumbo frames.