![Dell EMC Core XC750 Скачать руководство пользователя страница 80](http://html.mh-extra.com/html/dell/emc-core-xc750/emc-core-xc750_installation-and-service-manual_85118080.webp)
●
Mixing of DDR4 DIMM types (RDIMM, LRDIMM, and 3DS LRDIMM), within channels, for Integrated Memory Controller
(iMC), or across sockets are not supported.
●
Mixing of Intel Persistent Memory 200 series (BPS) operating modes (App Direct, Memory Mode) is not supported.
●
If only one DIMM is populated on a channel, then the DIMM should always be populated in the first slot in that channel
(white slot).
●
If a Intel Persistent Memory 200 series (BPS) and a DDR4 DIMM are populated on the same channel, always plug Intel
Persistent Memory 200 series (BPS) on second slot (black slot).
●
If the Intel Persistent Memory 200 series (BPS) is configured in Memory Mode, the recommended DDR4 to Intel Persistent
Memory 200 series (BPS) capacity ratio is 1:4 to 1:16 per iMC.
●
Intel Persistent Memory 200 series (BPS)' cannot be mixed with other Intel Persistent Memory 200 series (BPS) capacities
or NVDIMMs.
●
Mixing different capacities of RDIMMs and LRDIMMs are not allowed when Intel Persistent Memory 200 series (BPS) is
installed.
●
Intel Persistent Memory 200 series (BPS) of different capacities are not allowed.
●
VMware ESXi boot takes longer time when higher capacity of Intel Intel Persistent Memory 200 series (BPS) are configured
in AppDirect mode. This is expected as background ARS is going on the interleave sets and needs to be completed prior the
pMem datastore is mounted on ESXi.
●
App Direct (AD) can be populated symmetrically or asymmetrically across sockets.
●
In Memory mode (MM), symmetry across sockets is required.
●
Memory mode is not supported for the 6+1, 8+1 and 12+2 configurations irrespective of DDR to Intel Persistent Memory 200
series (BPS) capacity ratio.
●
In VMware ESXI environment, if BPS goal is changed between App Direct and Memory mode, it is recommended to sanitize
the DIMMs before creating a new goal.
●
Populate Intel Persistent Memory 200 series (BPS) in DIMM slot 1, unless Intel Persistent Memory 200 series (BPS) is the
only DIMM in that channel and then populate in DIMM slot 0.
For more information about the supported Intel Persistent Memory 200 series (BPS) configurations, see the
Dell
EMC Intel Persistent Memory 200 series (BPS) User's Guide
at
https://www.dell.com/support/home/products/server_int/
.
Table 29. Supported Intel Persistent Memory 200 series (BPS) for dual processor configurations
Configuration Description per
processor
Memory population rules
RDIMMs or LRDIMMs
Intel Persistent Memory 200
series (BPS)
Configuration 1 4 x RDIMMs, 4 x Intel
Persistent Memory 200
series (BPS)
Processor1 {A1, 2, 3, 4}
Processor2 {B1, 2, 3, 4}
Processor1 {A5, 6, 7 ,8}
Processor2 {B5, 6, 7, 8}
Configuration 2 6 x RDIMMs, 1 x Intel
Persistent Memory 200
series (BPS)
Processor1 {A1, 2, 3, 4, 5, 6}
Processor2 {B1, 2, 3, 4, 5, 6}
Processor1 {A7}
Processor2 {B7}
Configuration 3 8 x RDIMMs, 1 x Intel
Persistent Memory 200
series (BPS)
Processor1 {A1, 2, 3, 4, 5, 6, 7, 8}
Processor2 {B1, 2, 3, 4, 5, 6, 7, 8}
Processor1 {A9}
Processor2 {B9}
Configuration 4 8 x RDIMMs, 4 x Intel
Persistent Memory 200
series (BPS)
Processor1 {A1, 2, 3, 4, 5, 6, 7, 8}
Processor2 {B1, 2, 3, 4, 5, 6, 7, 8}
Processor1 {A9, 10, 11, 12}
Processor2 {B9, 10, 11, 12}
Configuration 5 8 x RDIMMs, 8 x Intel
Persistent Memory 200
series (BPS)
Processor1 {A1, 2, 3, 4, 5, 6, 7, 8}
Processor2 {B1, 2, 3, 4, 5, 6, 7, 8}
Processor1 {A9, 10, 11, 12, 13, 14, 15,
16}
Processor2 {B9, 10, 11, 12, 13, 14, 15,
16}
Configuration 6 12 x RDIMMs, 2 x Intel
Persistent Memory 200
series (BPS)
Processor1 {A1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,
12, 15, 16}
Processor2 {B1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,
12, 15, 16}
Processor1 {A5, 6}
Processor2 {B5, 6}
80
Installing and removing system components
Содержание EMC Core XC750
Страница 1: ...Dell EMC Core XC750 Installation and Service Manual September 2021 Rev 1 0 ...
Страница 19: ...Figure 13 Service information Figure 14 Memory information and system board connectors System overview 19 ...
Страница 21: ...Figure 19 System tasks Figure 20 Heat sink Figure 21 BOSS S2 Figure 22 Express service tag System overview 21 ...