Removing and Replacing Components
|
61
Remove an AC Power Supply in a non-redundant installation
Remove an AC Power Supply in a redundant installation
Removing and Replacing DC Power Supplies
If you are operating your E1200 DC chassis with redundant Power Supplies, you can install, remove, or
replace a Power Supply without affecting system operation. If you are operating your E1200 DC system
with only one Power Supply (the minimum), you must completely power off the system.
NOTE:
If there is a Power Supply failure (Power Supply LED is not lit or major alarm LED is lit), the entire
Power Supply Module must be replaced. There are no field serviceable parts inside the Power Supply unit.
Step
Task
1
Unplug the network interface cables connected to the line card or RPM.
2
Activate the disconnect switch at the Main power source or disconnect the AC cord at the remote power source.
3
Grip the handle and squeeze the thumb latch.
4
Slide the Power Supply out of the slot.
5
If you are replacing the Power Supply, go to
Installing AC Power Supplies on page 29
.
Step
Task
1
Tilt the AC-cord Retainer Safety cover approximately 15
o
and gently slide the cover away from the chassis.
2
Grip the handle and squeeze the thumb latch.
3
Slide the Power Supply out of the slot.
4
If you are replacing the Power Supply, go to
Installing AC Power Supplies on page 29
.
On/Standby
Switch
AC-Cord Retainer
Safety Cover
Power Supplies
AC Power Plugs
This retainer must be in place during normal operation.
Do not remove except for servicing
/
/
/
\
WARNING -
HIGH LEAKAGE CURRENT. EARTH CONNECTION
ESSENTIAL BEFORE CONNECTING SUPPLY.
COURANT DE FUITE ELEVE. RACCORDEMENT
A LA TERRE INDISPENSABLE AVANT LE
RACCORDEMENT AU RESEAU.
Содержание E1200i ExaScale
Страница 1: ...E1200i ExaScale Installation Guide ...
Страница 6: ...6 Contents w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 34: ...34 Installing AC Power Supplies w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 42: ...42 Installing DC Power Supplies w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 50: ...50 Installing RPMs Line Cards and SFM3s w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 58: ...58 Powering Up w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 66: ...66 Removing and Replacing Components w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 80: ...80 Alarms w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 90: ...90 Technical Support w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 93: ...Index 93 Test Power Supply and Fan Operability 31 40 U unpacking 19 23 W Warning 7 WEEE 86 ...
Страница 94: ...94 Index w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 95: ......
Страница 96: ...w w w d ell com support dell com Printed in the U S A ...