Introduction to RAID
39
Rebuilding can be done only in arrays with data redundancy, which includes
as RAID 1, 5, 10 and 50.
A hot spare can be used to rebuild disk drives in RAID 1, 5, 10, or 50
systems. If a hot spare is not available, the failed disk drive must be replaced
with a new disk drive so that the data on the failed drive can be rebuilt.
Using hot spares, PERC 3 can automatically and transparently rebuild failed
drives with user-defined rebuild rates. If a hot spare is available, the rebuild
can start automatically when a drive fails. PERC 3 automatically restarts the
system and the rebuild if the system goes down during a rebuild.
Rebuild Rate
The rebuild rate is the percentage of the compute cycles dedicated to
rebuilding failed drives. A rebuild rate of 100 percent means the system is
totally dedicated to rebuilding the failed drive.
The PERC 3 rebuild rate can be configured between 0% and 100%. At 0%,
the rebuild is done only if the system is not doing anything else. At 100%,
the rebuild has a higher priority than any other system activity. The default
rebuild rate is 30%.
Hot Swap
A hot swap is the manual replacement of a defective physical disk unit while
the computer is still running. When a new drive has been installed, a
rebuild will occur automatically if it is placed in the same drive bay as the
failed drive it is replacing. PERC 3 can be configured to detect the new disks
and to rebuild the contents of the disk drive automatically.
SCSI Drive States
The SCSI drive states are listed in Table 2-3.
Ta b l e 2 - 3 . S C S I D r i v e S t a t e s
State
Description
Online
(ONLIN)
The drive is working normally and is a part of a configured
logical drive.
Содержание DC, 3
Страница 8: ...6 w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 20: ...18 Figures ...
Страница 25: ...SE CT ION 1 Overview PERC 3 Overview PERC 3 Features ...
Страница 30: ...28 Overview w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 31: ...SE CT ION 2 Introduction to RAID RAID Definition PERC 3 Host Based RAID Solution Components and Features ...
Страница 43: ...SE CT ION 3 RAID Levels Overview Selecting a RAID Level RAID 0 RAID 1 RAID 5 RAID 10 RAID 50 ...
Страница 103: ...SE CT ION 8 PERC 3 SC Hardware Installation Requirements PERC 3 SC Card Layout Installation Steps ...
Страница 135: ...S EC T IO N 1 0 PERC 3 QC Hardware Installation Requirements PERC 3 QC Card Layout Installation Steps ...
Страница 150: ...148 PERC 3 QC Hardware Installation w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 214: ...212 Appendix A SCSI Cables and Connectors w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 215: ...S EC T IO N 1 5 Appendix B Warranties and Return Policy ...
Страница 248: ...246 Glossary w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 253: ......
Страница 254: ...w w w d e l l c o m s u p p o r t d e l l c o m Printed in the U S A P N 5C229 Rev A04 ...