PERC 3 BIOS Configuration Utility
183
A device selection window displays the devices connected to the
current controller. The failed drives have
FAIL
indicators.
2
Press the arrow keys to highlight any failed drives to be rebuilt.,
3
Press the spacebar to select the desired physical drives for rebuild.
4
After you select the physical drives, press <F10>.
5
Select
Yes
at the prompt.
The indicators for the selected drives change to
REBLD
. Rebuilding
can take some time, depending on the number of drives selected and
the drive capacities.
6
When rebuild is complete, press any key to continue.
7
Press <Esc> to display the
Management Menu
.
Using a Pre-loaded SCSI Drive “As-is”
NOTE:
To use a pre-
loaded system drive in the
manner described here,
you must make it the first
logical drive defined (for
example: LD1) on the
controller it is connected
to. This will make the
drive ID 0 LUN 0. If the
drive is not a boot device,
the logical drive number
is not critical.
You may have a SCSI hard drive that is already loaded with software. The
drive may be a boot disk containing an operating system. If so, add the
PERC device driver to this system drive before you switch to the PERC 3
and attempt to boot from it. You can use the PERC 3 controller as a SCSI
adapter for such a drive by performing the following steps.
1
Connect the SCSI drive to the channel on the PERC 3 controller, with
proper termination and TID settings.
2
Boot the computer.
3
Press <Ctrl><M> to start the BIOS Configuration Utility.
4
Select
Configure—
>
Easy Configuration
.
5
Press the cursor keys to select the pre-loaded drive.
6
Press the spacebar.
The pre-loaded drive should now become an array element.
7
Press <Enter>.
You have now declared the pre-loaded drive as a one-disk array. The
logical drive configuration screen displays.
8
Set the
Read Policy
on the
Advanced
Menu
.
9
Set the
Cache Policy
on the
Advanced
Menu
.
Содержание DC, 3
Страница 8: ...6 w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 20: ...18 Figures ...
Страница 25: ...SE CT ION 1 Overview PERC 3 Overview PERC 3 Features ...
Страница 30: ...28 Overview w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 31: ...SE CT ION 2 Introduction to RAID RAID Definition PERC 3 Host Based RAID Solution Components and Features ...
Страница 43: ...SE CT ION 3 RAID Levels Overview Selecting a RAID Level RAID 0 RAID 1 RAID 5 RAID 10 RAID 50 ...
Страница 103: ...SE CT ION 8 PERC 3 SC Hardware Installation Requirements PERC 3 SC Card Layout Installation Steps ...
Страница 135: ...S EC T IO N 1 0 PERC 3 QC Hardware Installation Requirements PERC 3 QC Card Layout Installation Steps ...
Страница 150: ...148 PERC 3 QC Hardware Installation w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 214: ...212 Appendix A SCSI Cables and Connectors w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 215: ...S EC T IO N 1 5 Appendix B Warranties and Return Policy ...
Страница 248: ...246 Glossary w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 253: ......
Страница 254: ...w w w d e l l c o m s u p p o r t d e l l c o m Printed in the U S A P N 5C229 Rev A04 ...