PERC 3 BIOS Configuration Utility
177
– In
Write-back
caching, the controller sends a data transfer
completion signal to the host when the controller cache has
received all the data in a transaction. This setting is not
recommended.
– In
Write-through
caching, the controller sends a data transfer
completion signal to the host when the disk subsystem has
received all the data in a transaction. This is the default setting for
cluster mode.
Write-through
caching has a data security advantage over
write-back
caching, whereas
write-back
caching has a performance advantage over
write-through
caching.
18
Set the
Read Policy
.
Read-ahead
enables the SCSI read-ahead feature for the logical drive.
You can set this parameter to
No-Read-Ahead
,
Read-ahead
, or
Adaptive
.
Adaptive
is the default setting.
–
No-Read-Ahead
specifies that the controller does not use read-
ahead for the current logical drive.
–
Read-ahead
specifies that the controller uses read-ahead for the
current logical drive.
–
Adaptive
specifies that the controller begins using read-ahead if
the two most recent disk accesses occurred in sequential sectors. If
all read requests are random, the algorithm reverts to
No-Read-
Ahead
, however, all requests are still evaluated for possible
sequential operation.
19
Set the
Read Policy
.
Cache Policy
applies to reads on a specific logical drive. It does not
affect the
Read-ahead
cache.
–
Cached I/O
specifies that all reads are buffered in cache memory.
–
Direct I/O
specifies that reads are not buffered in cache memory.
This is the default setting.
Direct I/O
does not override the cache policy settings. Data is
transferred to cache and the host concurrently. If the same data block
is read again, it comes from cache memory.
20
Press <Esc> to exit the
Advanced Menu
.
21
After you define the current logical drive, choose
Accept
and press
<Enter>.
Содержание DC, 3
Страница 8: ...6 w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 20: ...18 Figures ...
Страница 25: ...SE CT ION 1 Overview PERC 3 Overview PERC 3 Features ...
Страница 30: ...28 Overview w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 31: ...SE CT ION 2 Introduction to RAID RAID Definition PERC 3 Host Based RAID Solution Components and Features ...
Страница 43: ...SE CT ION 3 RAID Levels Overview Selecting a RAID Level RAID 0 RAID 1 RAID 5 RAID 10 RAID 50 ...
Страница 103: ...SE CT ION 8 PERC 3 SC Hardware Installation Requirements PERC 3 SC Card Layout Installation Steps ...
Страница 135: ...S EC T IO N 1 0 PERC 3 QC Hardware Installation Requirements PERC 3 QC Card Layout Installation Steps ...
Страница 150: ...148 PERC 3 QC Hardware Installation w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 214: ...212 Appendix A SCSI Cables and Connectors w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 215: ...S EC T IO N 1 5 Appendix B Warranties and Return Policy ...
Страница 248: ...246 Glossary w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 253: ......
Страница 254: ...w w w d e l l c o m s u p p o r t d e l l c o m Printed in the U S A P N 5C229 Rev A04 ...