Service Manual
8
Electronic Circuit Theory
2.1 Inverter PWM circuit
2.1.1)
Inverter Control circuit:(fig.2)
4.1
Fig.2
ON/OFF voltage signal coming from IF BD will enable U1 to work.C2 is
used to dump noise.
During the striking period, if the voltage at VSEN_POL(pin12) reaches a
threshold of approximately 2.85V, the transformer output voltage will be
regulated until the striking timer expires.
During normal operation, if the voltage at VSEN_POL(pin12) reaches the
present voltage at OVPT(pin16), the sink and source current of
SSTCMP(pin14) will stop and the TIMER(pin15) will be charged. Once
TIMER(pin15) expires and the abnormal condition still exists, U1 will
shutdown and latch.
Once the IC is enabled, when the voltage at VREF(pin21) rises to
approximately 4.0V, before the transformer output is present, and voltage at
Содержание 2209WA - UltraSharp - 22" LCD Monitor
Страница 1: ...Service Manual 0 Service Manual LCD Monitor 2209WA ...
Страница 25: ...Service Manual 24 8 Key Parts Pin Assignments 8 1 U105 TSUMU58EHJ LF ...
Страница 26: ...Service Manual 25 ...
Страница 27: ...Service Manual 26 ...
Страница 31: ...Service Manual 30 ...
Страница 32: ...Service Manual 31 Chapter 4 Disassembly Assembly 1 Exploded Diagram ...
Страница 36: ...Service Manual 35 Note 1 The arrows point out the direction of assembly ...
Страница 44: ...Service Manual 43 ...
Страница 80: ...Service Manual 79 ...
Страница 81: ...Service Manual 80 Attachment 3 PCB Layout power inverter bd inverter board Top Layer Bottom Layer ...
Страница 82: ...Service Manual 81 Main board Top Layer ...
Страница 83: ...Service Manual 82 Bottom Layer ...
Страница 84: ...Service Manual 83 Keypad USB convert board ...
Страница 85: ...Service Manual 84 ...