Service Manual
32
(Reprogramming Firmware Success)
Ø
If the firmware is reprogrammed successfully, “
Command: Fast flash write successful
” will be shown in
the Message text window. The total flashing time will also be calculated.
Ø
The “successful update” condition will make the motherboard bring “
Do-Re-Mi
” sound five times with
the interval of 500ms.
4.
Then AC OFF and ON to restart the monitor.
After repair, to ensure the quality you should do the following test and
adjustment.
Содержание 1907FPf
Страница 1: ...Service Manual 0 Service Manual LCD Monitor 1907FPf ...
Страница 55: ...Service Manual 54 ...
Страница 56: ...Service Manual 55 Attachment 2 Schematic ...
Страница 57: ...Service Manual 56 ...
Страница 58: ...Service Manual 57 ...
Страница 59: ...Service Manual 58 ...
Страница 60: ...Service Manual 59 ...
Страница 61: ...Service Manual 60 ...
Страница 62: ...Service Manual 61 ...
Страница 63: ...Service Manual 62 ...
Страница 64: ...Service Manual 63 ...
Страница 65: ...Service Manual 64 ...
Страница 66: ...Service Manual 65 ...
Страница 67: ...Service Manual 66 ...
Страница 68: ...Service Manual 67 ...
Страница 69: ...Service Manual 68 ...
Страница 70: ...Service Manual 69 ...
Страница 71: ...Service Manual 70 Attachment 3 PCB Layout Interface Board ...
Страница 72: ...Service Manual 71 ...
Страница 73: ...Service Manual 72 Power Inverter Board ...
Страница 74: ...Service Manual 73 Keypad Board ...
Страница 75: ...Service Manual 74 ...
Страница 76: ...Service Manual 75 USB Control Board ...
Страница 77: ...Service Manual 76 Inverter Control Board ...
Страница 78: ...Service Manual 77 Power Control Board ...
Страница 79: ...Service Manual 78 ...
Страница 80: ...Service Manual 79 ...