Expansion port cable labeling details
Primary port cable labeling details
Label part
number
Label
Port
Label part
number
Label
Port
046-004-467
B BE4
046-004-467_xx
B BE4
B BE4
B BE4
LCC B Port B
046-004-467
B BE4
046-004-467_xx
B BE4
B BE4
B BE4
LCC B Port A
046-004-460
A BE5
046-004-460_xx
A BE5
A BE5
A BE5
LCC A Port B
046-004-460
A BE5
046-004-460_xx
A BE5
A BE5
A BE5
LCC A Port A
046-004-468
B BE5
046-004-468_xx
B BE5
B BE5
B BE5
LCC B Port B
046-004-468
B BE5
046-004-468_xx
B BE5
B BE5
B BE5
LCC B Port A
2. Connect the existing DAE to the expansion DAE to extend that back-end.
If you have additional DAEs, add labels to the mini-SAS HD to mini-SAS HD
cables and use those cables to extend the bus. For more information about
cabling additional DAEs, see the associated
Hardware Information Guide
.
a. Connect port B on the link control card A (LCC A) of the lower-numbered
DAE to port A on the link control card A (LCC A) of the higher-numbered
DAE. [
1
]
LCC A is located on the lower portion of the DAE.
b. Connect port B on the link control card B (LCC B) of the lower-numbered
DAE to port A on the link control card B (LCC B) of the higher-numbered
DAE. [
2
]
LCC B is located on the upper portion of the DAE.
Connecting power to the DAE
Procedure
1. Verify that the cabinet circuit breakers are in the On position and that power is
connected to the cabinet.
2. Connect the power cables to the optional DAEs.
Cable and power up your DAE components
Connecting power to the DAE
65