background image

    Starts ONIE without ONIE Discovery Service

    Useful for running Diagnostics manually

ONIE: Uninstall OS

    Restore to factory defaults erases any installed OS

ONIE: Update ONIE

    For downloading and updating ONIE from a URL

ONIE: Embed ONIE

    For downloading and updating ONIE from a URL and erases any installed OS

During the initial setup, the switch boots to ONIE Install. ONIE Install boots with ONIE Discovery to the console, 

ONIE:

.

NOTE: 

For more information, see the 

Open Networking Hardware Diagnostic Guide

.

NOTE: 

After you have securely installed and powered on the S5048F-ON switch, to configure your switch, see your third-party 

ONIE-compatible OS or the Dell EMC OS documentation.

Check your switch

To confirm that ONIE is working properly, use the 

onie-sysinfo

 command. Run the 

onie-sysinfo

 command at the ONIE prompt.

ONIE:/ # onie-sysinfo x86_64-dell_<

platform

>_c25

ONIE:/ # onie-sysinfo –c 

(Machine arch)

x86_64

ONIE:/ # onie-sysinfo –v 

(ONIE Version programmed)

x.xx.x.x

ONIE:/ #

ONIE:/ # uname -a

Linux onie 3.2.35-onie+ #1 SMP Tue Dec 9 17:08:16 PST 2014 x86_64 GNU/Linux ONIE:/ #

ONIE:/ # lspci

00:00.0 Class 0600: 8086:1f0c

00:01.0 Class 0604: 8086:1f10

00:02.0 Class 0604: 8086:1f11

00:03.0 Class 0604: 8086:1f12

00:0e.0 Class 0600: 8086:1f14

00:0f.0 Class 0806: 8086:1f16

00:13.0 Class 0880: 8086:1f15

00:14.0 Class 0200: 8086:1f41

00:14.1 Class 0200: 8086:1f41

00:14.2 Class 0200: 8086:1f41

00:16.0 Class 0c03: 8086:1f2c

6:1f22 lass 0106: 8086:1f32

00:1f.0 Class 0601: 8086:1f38

00:1f.3 Class 0c05: 8086:1f3c

01:00.0 Class 0200: 14e4:b960 

(NPU PCI detection)

01:00.1

ONIE:/ #

ONIE service discovery

ONIE attempts to locate the installer through several discovery methods, as shown. To download and run an installer, the ONIE Service 
Discovery feature uses the first successful method found.

Passed from the boot loader.

Search locally attached storage devices for one of the ONIE default installer filenames—for example, USB.

Exact URLs from DHCPv4.

Report inexact URLs based on the DHCPv4 responses.

Query to the IPv6 link-local neighbors using HTTP for an installer.

Start TFTP waterfall—from the DHCPv4 option 66.

ONIE 

ifconfig eth0

 command examples

If none of the ONIE Service Discovery methods are successful, you can disable this using the 

onie-discovery-stop

 command.

Management ports

37

Содержание S5048F-ON

Страница 1: ...S5048F ON Installation Guide October 2017...

Страница 2: ...to hardware or loss of data and tells you how to avoid the problem WARNING A WARNING indicates a potential for property damage personal injury or death Copyright 2017 Dell Inc or its subsidiaries All...

Страница 3: ...ans and airflow 15 Fan combinations 15 Power 15 Storing components 16 4 S5048F ON switch installation 17 Unpack 17 Unpacking Steps 17 Rack or cabinet hardware installation 18 Rack mount safety conside...

Страница 4: ...mple 36 ONIE example 36 Check your switch 37 ONIE service discovery 37 8 Specifications 39 Chassis physical design 39 IEEE standards 40 Agency compliance 41 USA Federal Communications Commission state...

Страница 5: ...Class 1 laser product tag WARNING When no cable is connected visible and invisible laser radiation may emit from the aperture of the optical transceiver ports Avoid exposure to laser radiation Do not...

Страница 6: ...UTION The Caution icon signals information about situations that could result in equipment damage or loss of data WARNING The Warning icon signals information about hardware handling that could result...

Страница 7: ...trunking VLT and stacking and uplinks to aggregation and core switches The switch includes two hot swappable AC or DC power supply units PSUs and four hot swappable fan units The S5048F ON switch incl...

Страница 8: ...g unit CPU system with 8GB DDR III RAM 16GB iSLC mSATA SSD One 10 100 1000BaseT Ethernet management port Two hot swappable redundant power supplies Four hot swappable fan modules Standard 1U switch Ph...

Страница 9: ...SFP28 Port Link Activity LED 3 QSFP28 Port Link Activity LED 4 Master LED 5 System LED 6 Locator LED 7 Fan LED 8 Power LED 9 RJ 45 Ethernet Port LED Left is activity right is link Table 1 S5048F ON sw...

Страница 10: ...event causing a shutdown Blinking yellow PSU warning event power continues to operate Blinking green 1 0Hz Standby mode Blinking green 0 5Hz AC power cord unplugged LOCATOR LED System Beacon Off Locat...

Страница 11: ...ing yellow 1 second on off Port beacon Link Activity LED 4x25G mode or 4x10G mode Off No link Solid green Link operating at maximum speed 4x25G port Flashing green Link activity operating at maximum s...

Страница 12: ...4 Ethernet ports 48 SFP28 1 10 25GbE ports and 6 QSFP28 4x10 4x25 40 100GbE ports two AC or DC power supplies and four fan subsystems with airflow from the power supply side to the I O side Fan with a...

Страница 13: ...Figure 5 S5048F ON switch luggage tag 1 Service tag 2 MAC address 3 PPID 4 Express service code S5048F ON switch 13...

Страница 14: ...ty requirements Near an adequate power source Connect the switch to the appropriate branch circuit protection according to your local electrical codes Switch environmental temperature range is from 0...

Страница 15: ...w fan in your switch Do not mix reverse and normal airflows in a single S5048F ON switch For proper ventilation position the switch in an equipment rack or cabinet with a minimum of 5 inches 12 7 cm o...

Страница 16: ...40 C to 70 C 40 F to 158 F Store on a dry surface or floor away from direct sunlight heat and air conditioning ducts Store in a dust free environment NOTE ESD damage can occur when components are mish...

Страница 17: ...ation ReadyRails installation Switch installation Ground cable Optics installation Switch power up After switch placement Switch replacement Unpack NOTE Before unpacking the switch inspect the contain...

Страница 18: ...specified on the unit When you install multiple electrical components in a rack ensure that the total component power ratings do not exceed the circuit capabilities Overloaded power sources and extens...

Страница 19: ...ttached to the rail assembly 1 With the ReadyRails flange ears facing outward place one rail between the left and right vertical posts Align and seat the back flange rail pegs in the back vertical pos...

Страница 20: ...ar and unseat each rail Two post flush mount installation NOTE For more installation instructions see the installation labels attached to the rail assembly 1 For this configuration remove the castings...

Страница 21: ...o the post flange with two user supplied screws See item 3 4 Repeat this procedure for the second rail Two post center mount installation NOTE For more installation instructions see the installation l...

Страница 22: ...nstallation NOTE For more installation instructions see the installation labels attached to the rail assembly 1 For this installation remove the tool less latch castings from the front side of each Re...

Страница 23: ...o post configurations slide the switch into the rails in the same manner as the four post configurations 1U front rack installation Configure the rails that are attached to the switch NOTE For more in...

Страница 24: ...e previously mounted ReadyRails and slide the switch in until it is flush with front of rack To keep the switch from inadvertently sliding out of the rack and falling about 3 inches before you fully i...

Страница 25: ...o the switch you need one of the included M3 or M4 screws The switch ships with one of the following two configurations One threaded hole using an included M3 screw Two threaded holes using one of the...

Страница 26: ...tic to enter the port correctly The optic has a key that prevents it from being inserted incorrectly 2 Insert the optic into the port until it gently snaps into place NOTE When you cable the ports be...

Страница 27: ...face 1 Back up the switch configuration to your back up computer or laptop TFTP server copy running config tftp hostip filepath To establish a console connection to the switch CLI assign an IP address...

Страница 28: ...priate branch circuit protection as defined by your local electrical codes Verify that the remote power source complies with the switch input power specifications NOTE If you use a single PSU install...

Страница 29: ...e switch NOTE Ensure that you correctly install the PSU When you install the PSU correctly the power connector is on the right side of the PSU NOTE If you use a single PSU install a blank plate in the...

Страница 30: ...y using one power supply install the power supply in the first slot PSU1 Install a blank plate in the second slot PSU2 1 Disconnect the power cable from the PSU 2 Use the grab handle to slide the PSU...

Страница 31: ...nd 3 WARNING Do not cross the wires In the wiring block RTN aligns with RTN and 48V aligns with 48V 5 Insert the DC power connector into the power socket of the DC PSU Ensure that the connector pins f...

Страница 32: ...low is from the PSU to the I O panel the blue indicator is the reverse airflow direction All fans and PSUs in a configuration must be in the same airflow direction Environmental factors can decrease t...

Страница 33: ...tion reverse or normal If you mix the airflow direction to avoid damage to the switch you must correct the mixed airflow 1 Take the fan module out of the shipping box 2 Slide the module into the bay F...

Страница 34: ...ial console port CAUTION Ensure that any equipment attached to the serial port can support the required 115200 baud rate NOTE Before starting this procedure ensure that your PC has a 9 pin serial port...

Страница 35: ...itch 4 Power on the switch 5 Install the necessary USB device drivers To download the drivers go to www dell com support For assistance contact Dell EMC Technical Support 6 Open your terminal software...

Страница 36: ...le systems as indicated in the etc fstab file Before you install an OS After powering on the S5048F ON switch it goes through a power on self test POST POST runs every time the switch is initialized a...

Страница 37: ...4 x86_64 GNU Linux ONIE ONIE lspci 00 00 0 Class 0600 8086 1f0c 00 01 0 Class 0604 8086 1f10 00 02 0 Class 0604 8086 1f11 00 03 0 Class 0604 8086 1f12 00 0e 0 Class 0600 8086 1f14 00 0f 0 Class 0806 8...

Страница 38: ...1 53 33 Bcast 10 255 255 255 Mask 255 0 0 0 inet6 addr fe80 92b1 1cff fef4 9c76 64 Scope Link UP BROADCAST RUNNING MULTICAST MTU 1500 Metric 1 RX packets 18 errors 0 dropped 0 overruns 0 frame 0 TX pa...

Страница 39: ...s Agency compliance USA Federal Communications Commission statement European Union EMC directive conformance statement Japan VCCI compliance for class A equipment Korean certification of compliance Sa...

Страница 40: ...et 3 048 meters Maximum non operational altitude 39 370 feet 12 000 meters Shock Dell EMC Spec SV0115 Table 7 AC power requirements Parameter Specifications Power supply 100 240 VAC 50 60 Hz Maximum c...

Страница 41: ...ould void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful inte...

Страница 42: ...rmation Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions WARNING U...

Страница 43: ...stems FDA Regulation 21CFR 1040 10 and 1040 11 IEC 60950 1 2nd Ed including all National Deviations and Group Differences IEC 62368 1 Electromagnetic compatibility Emissions International CISPR32 Clas...

Страница 44: ...ppliances as applicable throughout the European Union This label is applied to various products to indicate that the product is not to be thrown away but rather reclaimed upon end of life per this Dir...

Страница 45: ...eb page and select your country from the drop down menu To obtain product specific information enter the 7 character service tag found on the luggage tag or the 11 digit express service code of your s...

Отзывы: