Carefully remove the switch from the container and place it on a secure and clean surface.

4

Remove all packing material.

5

Inspect the product and accessories for damage.

Rack or cabinet hardware installation

You may either place the switch on a rack shelf or mount the switch directly into a 19" wide, EIA-310- E-compliant rack. Rack mounting 
includes four-post, two-post, or threaded mounts. The ReadyRails system is provided for 1U front-rack and two-post installations.

The ReadyRails system includes separately packaged rail assemblies.

WARNING: 

This document is a condensed reference. Read the safety instructions in your 

Safety, Environmental, and Regulatory 

information booklet before you begin.

NOTE: 

The illustrations in this document are not intended to represent a specific switch.

NOTE: 

Do not the use the mounted ReadyRails as a shelf or a workplace.

Rack mount safety considerations

Rack loading—Overloading or uneven loading of racks may result in shelf or rack failure, possibly damaging the equipment and causing 

personal injury. Stabilize racks in a permanent location before loading begins. Mount the components starting at the bottom of the rack, 

then work to the top. Do not exceed your rack’s load rating.

Power considerations—Connect only to the power source specified on the unit. When you install multiple electrical components in a 

rack, ensure that the total component power ratings do not exceed the circuit capabilities. Overloaded power sources and extension 

cords present fire and shock hazards.

Elevated ambient temperature—If installed in a closed rack assembly, the operating temperature of the rack environment may be 

greater than the room ambient temperature. Use care not to exceed the 45°C maximum ambient temperature of the switch.

Reduced air flow—Install the equipment in the rack so that the amount of airflow required for safe operation of the equipment is not 

compromised.

Reliable earthing—Maintain reliable earthing of rack-mounted equipment. Pay particular attention to the supply connections other than 

the direct connections to the branch circuit, for example, use of power strips.

Do not mount the equipment with the back panel facing downward.

ReadyRails installation

To easily configure your rack for installation of your S5048F-ON switch, use the ReadyRails rack mounting system provided.
You can install the ReadyRails system using the 1U tool-less method or one of three possible 1U tooled methods—two-post flush mount, 
two-post center mount, or four-post threaded mount.

To begin installation, separate each rail assembly by sliding the inside rail out of the outside rail.

NOTE: 

For more installation instructions, see the installation labels attached to the rail assembly.

18

S5048F-ON switch installation

Содержание S5048F-ON

Страница 1: ...S5048F ON Installation Guide October 2017...

Страница 2: ...to hardware or loss of data and tells you how to avoid the problem WARNING A WARNING indicates a potential for property damage personal injury or death Copyright 2017 Dell Inc or its subsidiaries All...

Страница 3: ...ans and airflow 15 Fan combinations 15 Power 15 Storing components 16 4 S5048F ON switch installation 17 Unpack 17 Unpacking Steps 17 Rack or cabinet hardware installation 18 Rack mount safety conside...

Страница 4: ...mple 36 ONIE example 36 Check your switch 37 ONIE service discovery 37 8 Specifications 39 Chassis physical design 39 IEEE standards 40 Agency compliance 41 USA Federal Communications Commission state...

Страница 5: ...Class 1 laser product tag WARNING When no cable is connected visible and invisible laser radiation may emit from the aperture of the optical transceiver ports Avoid exposure to laser radiation Do not...

Страница 6: ...UTION The Caution icon signals information about situations that could result in equipment damage or loss of data WARNING The Warning icon signals information about hardware handling that could result...

Страница 7: ...trunking VLT and stacking and uplinks to aggregation and core switches The switch includes two hot swappable AC or DC power supply units PSUs and four hot swappable fan units The S5048F ON switch incl...

Страница 8: ...g unit CPU system with 8GB DDR III RAM 16GB iSLC mSATA SSD One 10 100 1000BaseT Ethernet management port Two hot swappable redundant power supplies Four hot swappable fan modules Standard 1U switch Ph...

Страница 9: ...SFP28 Port Link Activity LED 3 QSFP28 Port Link Activity LED 4 Master LED 5 System LED 6 Locator LED 7 Fan LED 8 Power LED 9 RJ 45 Ethernet Port LED Left is activity right is link Table 1 S5048F ON sw...

Страница 10: ...event causing a shutdown Blinking yellow PSU warning event power continues to operate Blinking green 1 0Hz Standby mode Blinking green 0 5Hz AC power cord unplugged LOCATOR LED System Beacon Off Locat...

Страница 11: ...ing yellow 1 second on off Port beacon Link Activity LED 4x25G mode or 4x10G mode Off No link Solid green Link operating at maximum speed 4x25G port Flashing green Link activity operating at maximum s...

Страница 12: ...4 Ethernet ports 48 SFP28 1 10 25GbE ports and 6 QSFP28 4x10 4x25 40 100GbE ports two AC or DC power supplies and four fan subsystems with airflow from the power supply side to the I O side Fan with a...

Страница 13: ...Figure 5 S5048F ON switch luggage tag 1 Service tag 2 MAC address 3 PPID 4 Express service code S5048F ON switch 13...

Страница 14: ...ty requirements Near an adequate power source Connect the switch to the appropriate branch circuit protection according to your local electrical codes Switch environmental temperature range is from 0...

Страница 15: ...w fan in your switch Do not mix reverse and normal airflows in a single S5048F ON switch For proper ventilation position the switch in an equipment rack or cabinet with a minimum of 5 inches 12 7 cm o...

Страница 16: ...40 C to 70 C 40 F to 158 F Store on a dry surface or floor away from direct sunlight heat and air conditioning ducts Store in a dust free environment NOTE ESD damage can occur when components are mish...

Страница 17: ...ation ReadyRails installation Switch installation Ground cable Optics installation Switch power up After switch placement Switch replacement Unpack NOTE Before unpacking the switch inspect the contain...

Страница 18: ...specified on the unit When you install multiple electrical components in a rack ensure that the total component power ratings do not exceed the circuit capabilities Overloaded power sources and extens...

Страница 19: ...ttached to the rail assembly 1 With the ReadyRails flange ears facing outward place one rail between the left and right vertical posts Align and seat the back flange rail pegs in the back vertical pos...

Страница 20: ...ar and unseat each rail Two post flush mount installation NOTE For more installation instructions see the installation labels attached to the rail assembly 1 For this configuration remove the castings...

Страница 21: ...o the post flange with two user supplied screws See item 3 4 Repeat this procedure for the second rail Two post center mount installation NOTE For more installation instructions see the installation l...

Страница 22: ...nstallation NOTE For more installation instructions see the installation labels attached to the rail assembly 1 For this installation remove the tool less latch castings from the front side of each Re...

Страница 23: ...o post configurations slide the switch into the rails in the same manner as the four post configurations 1U front rack installation Configure the rails that are attached to the switch NOTE For more in...

Страница 24: ...e previously mounted ReadyRails and slide the switch in until it is flush with front of rack To keep the switch from inadvertently sliding out of the rack and falling about 3 inches before you fully i...

Страница 25: ...o the switch you need one of the included M3 or M4 screws The switch ships with one of the following two configurations One threaded hole using an included M3 screw Two threaded holes using one of the...

Страница 26: ...tic to enter the port correctly The optic has a key that prevents it from being inserted incorrectly 2 Insert the optic into the port until it gently snaps into place NOTE When you cable the ports be...

Страница 27: ...face 1 Back up the switch configuration to your back up computer or laptop TFTP server copy running config tftp hostip filepath To establish a console connection to the switch CLI assign an IP address...

Страница 28: ...priate branch circuit protection as defined by your local electrical codes Verify that the remote power source complies with the switch input power specifications NOTE If you use a single PSU install...

Страница 29: ...e switch NOTE Ensure that you correctly install the PSU When you install the PSU correctly the power connector is on the right side of the PSU NOTE If you use a single PSU install a blank plate in the...

Страница 30: ...y using one power supply install the power supply in the first slot PSU1 Install a blank plate in the second slot PSU2 1 Disconnect the power cable from the PSU 2 Use the grab handle to slide the PSU...

Страница 31: ...nd 3 WARNING Do not cross the wires In the wiring block RTN aligns with RTN and 48V aligns with 48V 5 Insert the DC power connector into the power socket of the DC PSU Ensure that the connector pins f...

Страница 32: ...low is from the PSU to the I O panel the blue indicator is the reverse airflow direction All fans and PSUs in a configuration must be in the same airflow direction Environmental factors can decrease t...

Страница 33: ...tion reverse or normal If you mix the airflow direction to avoid damage to the switch you must correct the mixed airflow 1 Take the fan module out of the shipping box 2 Slide the module into the bay F...

Страница 34: ...ial console port CAUTION Ensure that any equipment attached to the serial port can support the required 115200 baud rate NOTE Before starting this procedure ensure that your PC has a 9 pin serial port...

Страница 35: ...itch 4 Power on the switch 5 Install the necessary USB device drivers To download the drivers go to www dell com support For assistance contact Dell EMC Technical Support 6 Open your terminal software...

Страница 36: ...le systems as indicated in the etc fstab file Before you install an OS After powering on the S5048F ON switch it goes through a power on self test POST POST runs every time the switch is initialized a...

Страница 37: ...4 x86_64 GNU Linux ONIE ONIE lspci 00 00 0 Class 0600 8086 1f0c 00 01 0 Class 0604 8086 1f10 00 02 0 Class 0604 8086 1f11 00 03 0 Class 0604 8086 1f12 00 0e 0 Class 0600 8086 1f14 00 0f 0 Class 0806 8...

Страница 38: ...1 53 33 Bcast 10 255 255 255 Mask 255 0 0 0 inet6 addr fe80 92b1 1cff fef4 9c76 64 Scope Link UP BROADCAST RUNNING MULTICAST MTU 1500 Metric 1 RX packets 18 errors 0 dropped 0 overruns 0 frame 0 TX pa...

Страница 39: ...s Agency compliance USA Federal Communications Commission statement European Union EMC directive conformance statement Japan VCCI compliance for class A equipment Korean certification of compliance Sa...

Страница 40: ...et 3 048 meters Maximum non operational altitude 39 370 feet 12 000 meters Shock Dell EMC Spec SV0115 Table 7 AC power requirements Parameter Specifications Power supply 100 240 VAC 50 60 Hz Maximum c...

Страница 41: ...ould void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful inte...

Страница 42: ...rmation Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions WARNING U...

Страница 43: ...stems FDA Regulation 21CFR 1040 10 and 1040 11 IEC 60950 1 2nd Ed including all National Deviations and Group Differences IEC 62368 1 Electromagnetic compatibility Emissions International CISPR32 Clas...

Страница 44: ...ppliances as applicable throughout the European Union This label is applied to various products to indicate that the product is not to be thrown away but rather reclaimed upon end of life per this Dir...

Страница 45: ...eb page and select your country from the drop down menu To obtain product specific information enter the 7 character service tag found on the luggage tag or the 11 digit express service code of your s...

Отзывы: