Troubleshooting and problem solving
These procedures are intended to be used only during initial configuration, for the purpose of verifying that hardware setup is successful.
They are not intended to be used as troubleshooting procedures for configured systems using production data and I/O.
Topics:
•
•
•
•
•
•
Overview
The enclosure system includes a Storage Enclosure Processor (SEP) and associated monitoring and control logic to enable it to diagnose
problems with the enclosure’s power, cooling, and drive systems. Management interfaces allow for provisioning, monitoring, and managing
the storage system.
NOTE:
when conducting system diagnostics.
LEDs
LED colors are used consistently throughout the enclosure and its components for indicating status:
•
Green: good or positive indication
•
Blinking green/amber: non-critical condition
•
Amber: critical fault
•
Blue: Controler/IOM identification
2U enclosure LEDs
PCM LEDs
Under normal conditions, the PCM OK LEDs will be a constant green.
Table 11. PCM LED states
PCM OK
(Green)
Fan Fail
(Amber)
AC Fail
(Amber)
DC Fail
(Amber)
Status
Off
Off
Off
Off
No AC power on any PCM
Off
Off
On
On
No AC power on this PCM only
On
Off
Off
Off
AC present; PCM working correctly