CAUTION:
Wire the unit with copper only, unless otherwise specified, use only 10 American Wire Gauge (AWG) wire
rated minimum 90ºC for source and return. Protect the –(48–60) V DC (1 wire) with a branch circuit over-current
protection rated 50 A for DC with a high interrupt current rating.
CAUTION:
Connect the equipment to a –(48–60) V DC supply source that is electrically isolated from the AC source
(reliably grounded –(48–60) V DC SELV source). Ensure that the –(48–60) V DC source is efficiently secured to earth
(ground).
NOTE:
A readily accessible disconnect device that is suitably approved and rated shall be incorporated in t he field
wiring.
Input requirements
•
Supply voltage: –(48–60) V DC
•
Current consumption: 32 A (maximum)
Kit contents
•
Dell part number 6RYJ9 terminal block or equivalent (1)
•
#6-32 nut equipped with lock washer (1)
Required tools
Wire-stripper pliers capable of removing insulation from size 10 AWG solid or stranded, insulated copper wire.
NOTE:
Use alpha wire part number 3080 or equivalent (65/30 stranding).
Required wires
•
One UL 10 AWG, 2 m maximum (stranded) black wire [–(48–60) V DC].
•
One UL 10 AWG, 2 m maximum (stranded) red wire (V DC return).
•
One UL 10 AWG, 2 m maximum, green with a yellow stripe, stranded wire (safety ground).
System board
Removing the system board
Prerequisites
CAUTION:
If you are using the Trusted Platform Module (TPM) with an encryption key, you may be prompted to create
a recovery key during program or System Setup. Be sure to create and safely store this recovery key. If you replace this
system board, you must supply the recovery key when you restart your system or program before you can access the
encrypted data on your drives.
CAUTION:
Do not attempt to remove the TPM plug-in module from the system board. Once the TPM plug-in module is
installed, it is cryptographically bound to that specific system board. Any attempt to remove an installed TPM plug-in
module breaks the cryptographic binding, and it cannot be re-installed or installed on another system board.
Follow the safety guidelines listed in
Safety instructions
.
Follow the procedure listed in
Before working inside your system
.
Remove the following:
CAUTION:
Do not lift the s ystem board by holding a memory module, processor, or other components.
Air shroud
All expansion cards and risers
Integrated storage controller card
Internal USB key (if applicable)
Internal USB key (if applicable)
158
Installing and removing syst em components