Figure 9. Installing the sled into the enclosure
Next steps
Restart the compute sled using the OpenManage Enterprise- Modular interface and assign the storage sled if not already assigned and
power on the compute sleds to which the storage sled is mapped.
Drive drawer
NOTE:
The enclosure fans may spin at a higher speed, to provide extra cooling when the drive drawer is opened. After
five minutes the fans speed increases to their maximum with the storage sled health indicator blinking amber.
CAUTION:
1. The drive drawer should not be in service position for longer than five minutes at 35°C condition to maintain proper
thermal temperature.
2. The drive drawer should not be in service position for longer than three minutes at fresh air environment to maintain
proper thermal temperature.
Opening the drive drawer
Prerequisites
Follow the safety guidelines listed in
Steps
1. Slide the drive drawer release latch to unlock the drawer.
2. Pull the drive drawer out of the sled.
Installing and removing system components
17