Steps
1
Connect the data cable to the riser.
2
Insert the keyed end of the M.2 SATA riser into the lock on the system board.
3
Align and insert the edge connector into the connector on the system board.
4
Using the Phillips #2 screwdriver, tighten the screw to secure the riser to the sled.
Figure 61. Installing the M.2 SATA x16 riser
Next steps
1
Install the sled into the enclosure
2
Follow the procedure listed in
After working inside your enclosure
.
Removing the M.2 SATA card
Prerequisites
1
Follow the safety guidelines listed in
..
2
Follow the procedure listed in
Before working inside your enclosure
3
Remove the sled from the enclosure
4
If applicable,
remove the expansion card riser assembly
5
Remove the M.2 x16 riser or the M.2 SATA x8 mezzanine card
NOTE:
The procedure to remove the M.2 SATA x8 mezzanine card is similar to removing a mezzanine card.
Steps
1
Using the Phillips #1 screwdriver, unscrew the screw that secures the M.2 card to the board.
2
Pull the card out of the connector and lift the card away.
112
Installing and removing enclosure components
Содержание PowerEdge C6420
Страница 8: ...Figure 1 Supported configurations for PowerEdge C6420 8 Dell EMC PowerEdge C6420 overview ...
Страница 16: ...Mechanical overview Figure 10 Mechanical overview 16 Dell EMC PowerEdge C6420 overview ...
Страница 17: ...Memory information Figure 11 Memory information Dell EMC PowerEdge C6420 overview 17 ...
Страница 18: ...Jumper settings Figure 12 Jumper settings 18 Dell EMC PowerEdge C6420 overview ...
Страница 68: ...Figure 17 Installing a sled 68 Installing and removing enclosure components ...
Страница 101: ...Figure 48 Removing an expansion card Installing and removing enclosure components 101 ...
Страница 103: ...Figure 50 Removing the expansion card filler bracket Installing and removing enclosure components 103 ...