NOTE:
To enable the BOSS S2 in the system, ensure that the BIOS firmware version is 1.5.5 and iDRAC firmware version is
4.30.30.30 or later.
Before you begin the installation or removal process, follow the
and
before working inside the system
instructions.
Table 31. BOSS S2 kit components
R7525 (quantity)
Components in kit
NA
BOSS cover
1
M3 x 0.05 x 4.5 mm screws
1
BOSS signal cable
1
BOSS power cable
1
BOSS-S2 controller card module
1 or 2*
BOSS-S2 card carrier
1 or 2*
M.2 SSD
2
M.2 240 GB information label
2
M.2 480 GB information label
1
BOSS card filler
1
Tech sheet
To remove the BOSS blank :
.
2. Use a screwdriver to push out the BOSS blank from inside of the BOSS S2 controller card module slot.
Figure 145. Removing the BOSS blank
To install the BOSS blank:
.
2. Align the BOSS blank at an angle with the BOSS S2 controller card module slot.
3. Slot the BOSS blank into the BOSS S2 controller card module slot until it is firmly seated.
164
Upgrade Kits