Table 12. DD6800 with DS60 primary node cabling instructions (continued)
String
(Loop)
I/O - Port
Shelf Port
Length
2
I/O 7 - Port 1
A controller port 0 of shelf V2.1
2M
2
I/O 2 - Port 1
B controller port 0 of the highest number shelf in V2
2M
3
I/O 7 - Port 2
A controller port 0 of shelf V3.1
2M
3
I/O 2 - Port 2
B controller port 0 of the highest number shelf in V3
2M
4
I/O 7 - Port 3
A controller HOST
port of the SSD shelf
2M
4
I/O 2 - Port 3
B controller HOST
port of the SSD shelf
2M
a.
Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be used.
Table 13. DD6800 with DS60 standby node cabling instructions
String
(Loop)
I/O - Port
Shelf Port
Length
1
I/O 7 - Port 0
B controller port 2 of shelf V1.1
2M
1
I/O 2 - Port 0
A controller port 2 of the highest number shelf in V1
2M
2
I/O 7 - Port 1
B controller port 2 of shelf V2.1
2M
2
I/O 2 - Port 1
A controller port 2 of the highest number shelf in V2
2M
3
I/O 7 - Port 2
B controller port 2 of shelf V3.1
2M
3
I/O 2 - Port 2
A controller port 2 of the highest number shelf in V3
2M
4
I/O 7 - Port 3
A controller EXPANSION
port of the SSD shelf
2M
4
I/O 2 - Port 3
B controller EXPANSION
port of the SSD shelf
2M
a.
Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be used.
56
Connect Cables and Power On