52
Number __________
Circuit breaker body (required)
frame
1600AF
□
2000AF
□
2500AF
□
3200AF
□
4000AF
□
6300AF
□
Breaking capacity
N
□
H
□
Note:6300AF have not H
Rated current
400A
□
630A
□
630A
□
2000A
□
630A
□
4000A
□
630A
□
800A
□
800A
□
2500A
□
800A
□
5000A
□
800A
□
1000A
□
1000A
□
3200A
□
1000A
□
6300A
□
1000A
□
1250A
□
1250A
□
1250A
□
1250A
□
1600A
□
1600A
□
1600A
□
1600A
□
2000A
□
2000A
□
2000A
□
2500A
□
2500A
□
3200A
□
4000A
□
poles
3P
□
4P
□
frequency
50Hz
□
60Hz
□
Installation method
Draw-out vertical
□
Draw-out vertical
□
Fixed horizontal
□
Fixed vertical
□
Note: vertical wiring is only limited to 1600N & H and 4000N & H
Note: 6300AF have not fixed
ETU
iTR326
□
iTR26A
(standar
d)
□
iTR326H
□
Note:6300AF have not iTR326
Communication protocol (iTR326H only)
Modbus
(default)
□
Profibus
□
Devicene
t
□
Remote operation
Shunt coil
AC230V
□
AC400V
□
DC110V
□
DC220V
□
Closing coil
AC230V
□
AC400V
□
DC110V
□
DC220V
□
Electric operating mechanism
AC230V
□
AC400V
□
DC110V
□
DC220V
□
Undervoltage coil
No
□
AC230V
□
AC400V
□
Provide delay seconds (for 1600AF/4000AF)
0.5s
□
1s
□
1.5s
□
3s
□
Provide delay seconds (for 2000AF/2500AF/3200AF/6300AF)
1s
□
3s
□
5s
□
7.5 s
□
Indicating contact
Auxiliary switch
frame
Auxiliary switch
Note:
The default configuration
is 4 on 4 off
1600N&H
4 on 4 off
□
2000N&H
4 on 4 off
□
6 on 6 off
□
2500N&H
4 on 4 off
□
6 on 6 off
□
3200N&H
4 on 4 off
□
6 on 6 off
□
4000N&H
4 on 4 off
□
6 on 6 off
□
8 on 8 off
□
12 on 12 off
□
6300N
4 on 4 off
□
6 on 6 off
□
Three position indicating contact □
Closing preparation indicating contact
□
Note:
Please contact the manufacturer for 12 on 12 off
Common accessories - lock
Opening lock:
One lock one key
□
Mechanical
interlock:
Cable
interlock
□
Mechanical interlocking of cross
frame:
□
Two locks and one
key
□
Lever
interlock
□
Drawer door interlock:
□
Three locks and two
keys
□
2 sets
□
On off button lock:
□
Key combination
lock
□
3 sets
□
Safety damper lock:
□(4000AF only)
Note: 1600AF without cable interlock (3 sets) and lever interlock (3
sets)
Note: key lock or mechanical interlock shall be selected. If combined lock is selected, the product shall be matched with
the previously selected key lock or mechanical interlock
Common accessories - ETU accessories
External transformer:
Power converter
□
Grounding transformer
□
N-phase external transformer
□
Signal conversion module
□
Leakage transformer
□
Note: Power converter is
standard accessory
Note: N-phase external transformer is only
applicable to 3P+N
Note: leakage transformer, grounding transformer and signal conversion module are only applicable to
iTR326H ETU
Common accessories - protection and connection accessories
Interphase partition (standard)
□
(4000A in 4000af
without interphase
partition)
Vertical l adapter
□
(2000AF only)
Secondary terminal
guard
□
Door frame (standard)
□
Extension terminal
□
(1600AF only)
(only draw-out)
instructions
Power module installation instructions
□
Installation instruction of undervoltage delay unit
□
Installation manual of mechanical interlock
□
Note:
In general application, the following standard configuration can be used: shunt coil, closing coil, electric operation mechanism, interphase partition, door frame,
power module, auxiliary switch 4 on 4 off, iTR326A ETU
If you need other special application accessories, please check in the selection table and configuration table
Appendix-
Model selection table