International Work Top & Undercounter Refrigerators & Freezers Original User Manual
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
14
Freezer Wiring Diagram - 400 Series
3) UNIT SHOWN WITH COMPRESSOR
RUNNING AND DOORS CLOSED
2) THIS UNIT MUST BE GROUNDED
1) USE COPPER CONDUCTORS ONLY
NOTES:
CONDENSOR FAN
DEFROST
EVAPORATOR FAN
HEATER RELAY
1.1,2,3 2.1,2,3 3.1,2,3
COMPRESSOR
RELAY
CONTROL
TEMPERATURE
LED DISPLA
Y
(IF USED
)
3
L
EV
AP C
OIL
SENSOR
SENSOR
CABINE
T AIR
1
C
FAN RELAY
CIRCUIT
CONTROL
4
H
6
F
5
N
COMPRESSOR
M
M
M
HI-LIMIT
HEATER
REVISIONS
RELEASE TO PRODUCTION
1
REV
DESCRIPTION
2/28/2012
DATE
L ENNIS
APPROVED
LABEL,WIRING,400 FRZ,230V/50HZ,CE
COVINGTON, TN
ENODIS
1
Reach-in Divison
REV.
LOCATION
DIMENSIONS ARE IN INCHES
TOLERANCES
ALL PARTS TO BE DEBURRED AND EDGES
UNLESS OTHERWISE SPECIFIED
THIRD ANGLE
PROJECTION
The contents of this document are
PROPRIETARY TO THE DELFIELD COMPANY
and are not to be disclosed to others
intended without the written approval
or used for purposes other than
PROPRIETARY
of The Delfield Company.
MATERIAL
BROKEN .010 MAXIMUM.
ANG. ±
.XXX ±
.XX ±
.X ±
.010
1
.03
.1
C
DO NOT SCALE DRAWING
SCALE
CHECKED:
L ENNIS
DRAWN:
MFG:
QA:
PURCH:
SIGNATURE
DATE
2/28/2012
DESCRIPTION
SIZE
9294484
SHEET
1 OF 1
DWG. NO.
LINE VOLTAGE
220V/50Hz/1Ph
SEE NAMEPLATE FOR MAXIMUM
FUSE SIZE
BLOCK
TERMINAL
BR
OWN
L
G
GRN-
YEL
BL
UE
N
YELLOW
ORANGE
VIOLET