Location
Be sure the location chosen has a floor strong enough to support
the total weight of the cabinet and contents. Allow for a total load
of approximately 1000 pounds (450kg) per door section. Reinforce
the floor if necessary to provide for maximum loading. For the most
efficient operation, be sure to provide good air circulation inside and
out.
Inside cabinet:
Take care not to block air flow to the fans or heating
elements and allow space along the front, back and sides.
Outside cabinet:
Be sure that the unit has access to ample air; avoid
hot corners and locations near stoves and ovens. Always provide a
minimum of 12 “ (30.5 cm) of clearance above the unit that is open to
the front.
If the doors need to be removed during installation, remove the door
by lifting it up and easing it out of the hinge brackets.
Leveling
A level cabinet looks better and will perform better because the doors
will line up with the door frames properly, and the cabinet will not be
subject to unnecessary strain.
Unit Installation - Surface Mounted
The surface mounting installation method uses stainless steel ramps
to allow entry into the cabinet (one ramp provided with roll-in models,
two with roll-through models).
1. Install a minimum of 1” (2.5cm) of cork insulation (or equivalent)
in the space under the unit. The insulation should be recessed.
2. Set the unit in place and seal to the floor.
3. Install ramp(s). On refrigerators or freezers, when the ramps are
properly installed, heat from the heater wire will be transferred to
the ramp to prevent condensation.
Door installation
If the doors need to be removed during installation remove the door by
lifting it up and easing it out of the hinge brackets.
Electrical connection
Refer to the amperage data on pages 3-7 or the
serial tag data and your local code or the National
Electrical Code to be sure the unit is connected
to the proper power source. A protected circuit
of the correct voltage and amperage must be run
for connection of the supply cord or permanent
connection to the unit. The power must be
turned off and disconnected whenever performing
maintenance or repair functions.
Permanently connected units must be connected in
accordance with NEC Article 422 Appliances.
C-Disconnecting means. It is the responsibility of
the end user to provide the disconnect means to
satisfy the authority having jurisdiction.
Large cabinets should always be moved with
extreme care and caution.