ELECTRONIC CONTROLS
MECHANICAL CONTROLS
THERMOST
AT
ERC2
YELLOW
BLUE
WHITE
PURPLE
BLACK
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
PURPLE
BLACK
BROWN
BROWN
SOL
COND
FRAME HEATER
1 PER DOOR OPENING
DS2
EVAP. FAN(S)
CONDENSATE. HEATER
HLS
ELS
BALLAST
FLUORESCENT LAMP
PSS
LI
N
G
PSS
POWER SUPPLY SWITCH
SOL
SOLENOID VALVE
HLS
HIGH LIMIT SAFETY
COND
CONDENSING UNIT
ELS
EXTERNAL LIGHT SWITCH
DS
DOOR SWITCH
DLFD
DEFROST LIMIT FAN DELAY
NOTE: Display lights are on “G” models only. Solenoid valve and conden-
sate heaters are on remote models only. Power cord may or may not be
provided. Power switch used with electronic controls only.
WIRING DIAGRAM 115v MERIDIAN FREEZER
2-3 DOOR
MODELS
ONLY
BLUE
YELLOW
BLACK
WHITE
PURPLE
WHITE
PURPLE
BROWN
YELLOW
BLACK
DEFROST HEATER
BLUE
DS1
INTERIOR LIGHT
WHITE
HLS
WHITE
WHITE
WHITE
BLUE
RED
BLACK
WIRING DIAGRAM MERIDIAN FREEZER 115v
220V
WHITE
BROWN
BLACK
YELLOW
CYCLE TIME
DEFROST
X
P2
CR
P3
DEFROST
ON LED
DEFROST
INITIATE
DEFROST
LINE NO.
COMP
LINE NO.
AEROTRONICS
P1
N
TIMED RELEASE
SOLENOID
PARAGON
8145-008
BROWN
BLUE
BROWN
DLFD
BROWN
BLUE
BROWN
Содержание Meridian MHR1-G