Safety Notices

n

Warning

Read this manual thoroughly before operating, installing 

or performing maintenance on the equipment. Failure 

to follow instructions in this manual can cause property 

damage, injury or death.

 DANGER

Do not install or operate equipment that has been 

misused, abused, neglected, damaged, or altered/

modified from that of original manufactured 

specifications.

 DANGER

Keep power cord AWAY from HEATED surfaces. DO NOT 

immerse power cord or plug in water. DO NOT let power 

cord hang over edge of table or counter.

 DANGER

All utility connections and fixtures must be maintained 

in accordance with local and national codes.

 DANGER

Use appropriate safety equipment during installation 

and servicing.

n

Warning

Do not damage the refrigeration circuit when installing, 

maintaining or servicing the unit.

n

Warning

Authorized service representatives are obligated to 

follow industry standard safety procedures, including, 

but not limited to, local/national regulations for 

disconnection / lock out / tag out procedures for all 

utilities including electric, gas, water and  steam.

n

Warning

Do not store or use gasoline or other flammable vapors 

or liquids in the vicinity of this or any other appliance. 

Never use flammable oil soaked cloths or combustible 

cleaning solutions, for cleaning.

n

Warning

This product contains chemicals known to the State 

of California to cause cancer and/or birth defects or 

other reproductive harm. Operation, installation, and 

servicing of this product could expose you to airborne 

particles of glasswool or ceramic fibers, crystalline 

silica, and/or carbon monoxide.  Inhalation of airborne 

particles of glasswool or ceramic fibers is known to the 

State of California to cause cancer.  Inhalation of carbon 

monoxide is known to the State of California to cause 

birth defects or other reproductive harm.

n

Warning

Do not use electrical appliances or accessories other 

than those supplied by the manufacturer.

n

Warning

Use caution when handling metal surface edges of all 

equipment.

n

Warning

This appliance is not intended for use by persons 

(including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision 

concerning use of the appliance by a person responsible 

for their safety. Do not allow children to play with this 

appliance.

Notice

Proper installation, care and maintenance are 

essential for maximum performance and trouble-free 

operation of your equipment. Visit our website www.

mtwkitchencare.com for manual updates, translations, 

or contact information for service agents in your area.

Содержание F15MC48D-E

Страница 1: ... Installation Operation and Maintenance Manual This manual is updated as new information and models are released Visit our website for the latest manual Part Number 9291460 11 17 F5 and F15 Series Refrigerated Display Cases ...

Страница 2: ...Never use flammable oil soaked cloths or combustible cleaning solutions for cleaning nWarning This product contains chemicals known to the State of California to cause cancer and or birth defects or other reproductive harm Operation installation and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers crystalline silica and or carbon monoxide Inhalation o...

Страница 3: ...ounter Installation For 60 72 Units 11 Electrical Service 12 Voltage 12 Ground Fault Circuit Interrupter 12 Rated Amperages Horsepower Voltage Power Cord Chart 12 Drain Connections 13 Refrigeration 13 Remote Option Installation 14 F5 Remote Models 14 F15 Remote Models 14 Section 3 Operation Refrigerated Display Cases 15 Display Lock Operation 15 115Volt Power Switch 16 115Volt Light Switch 16 115V...

Страница 4: ...enance General Cleaning 21 Interior Cleaning 22 Gaskets 22 Preventing Blower Coil Corrosion 22 Exterior Cleaning 22 Drain 22 Cleaning The Condenser Coil 23 Cleaning The Condensate Evaporator 23 Remote Models Only 23 Door Maintenance 23 Doors With Hinges 23 Sliding Doors 23 ...

Страница 5: ... E F15SC72D E Serial Number Information The serial number is on the identification plate that also includes the model number Self contained F5 series identification plate is located near the condensing unit The serial number on all self contained F15 series units is located behind the compressor housing Always have the serial number of your unit available when calling for parts or service Warranty...

Страница 6: ...6 Part Number 9291460 11 17 General Information Section 1 THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 7: ...perate this equipment in outdoor areas The location selected for the equipment must meet the following criteria If any of these criteria are not met select another location Units are intended for indoor use only The location MUST be level stable and capable of supporting the weight of the equipment The location MUST be free from and clear of combustible materials Equipment MUST be level both front...

Страница 8: ... 57 145cm F5PC60DV 60 152cm 33 38 85cm 57 145cm F5SC60DV 60 152cm 33 38 85cm 57 145cm F5MC72DV 72 183cm 31 5 80cm 57 145cm F5PC72DV 72 183cm 33 38 85cm 57 145cm F5SC72DV 72 183cm 33 38 85cm 57 145cm Self Contained Serview F15MC48DV 48 122cm 31 5 80cm 78 198cm F15PC48DV 48 122cm 33 38 85cm 78 198cm F15SC48DV 48 122cm 33 38 85cm 78 198cm F15MC60DV 60 152cm 31 5 80cm 78 198cm F15PC60DV 60 152cm 33 38...

Страница 9: ...ew F15MC48D E 19 6ft2 18209cm2 22 3ft3 631L 9 15ft3 259L F15PC48D E 21 4ft2 19881cm2 25ft3 708L 9 15ft3 259L F15SC48D E 21 4ft2 19881cm2 24 3ft3 688L 9 15ft3 259L F15MC60D E 25ft2 23226cm2 28 4ft3 804L 12 13ft3 343L F15PC60D E 27 3ft2 25363cm2 31 9ft3 903L 12 13ft3 343L F15SC60D E 27 3ft2 25363cm2 31ft3 878L 12 13ft3 343L F15MC72D E 30 5ft2 28335cm2 34 6ft3 980L 18 04ft3 511L F15PC72D E 33 3ft2 30...

Страница 10: ... a minimum of 14 36cm up from the cabinet bottom inside the partitions 3 The unit requires airflow to the compressor Two louvers are provided with each unit NOTE Any restriction to the proper air flow will void the compressor warranty Louver cut outs are 22 x 11 56cm by 28cm 143in2 923cm2 is required at both the intake and discharge Cut outs are to begin a maximum of 4 00 10cm from the counter top...

Страница 11: ...net bottom inside the partitions 3 The unit requires airflow to the compressor Two louvers are provided with each unit NOTE Any restriction to the proper air flow will void the compressor warranty Louver cut outs are 22 x 11 56cm by 28cm 174in2 1123cm2 is required at both the intake and discharge Cut outs are to begin a maximum of 4 00 10cm from the counter top Install louvers on the front and bac...

Страница 12: ...n to energize our equipment If code requires the use of a GFCI GFI then you must follow the local code The circuit must be dedicated sized properly and there must be a panel GFCI GFI breaker We do not recommend the use of GFCI GFI outlets to energize our equipment as they are known for more intermittent nuisance trips than panel breakers RATED AMPERAGES HORSEPOWER VOLTAGE POWER CORD CHART Display ...

Страница 13: ... Display Base Display Self Contained Drop In F5MC36DV N A 4780 N A 425 32oz F5PC36DV N A 4780 N A 750 32oz F5SC36DV N A 4780 N A 510 32oz F5MC48DV N A 5335 N A 520 32oz F5PC48DV N A 5335 N A 900 32oz F5SC48DV N A 5335 N A 750 32oz F5MC60DV N A 6900 N A 600 48oz F5PC60DV N A 6900 N A 1050 48oz F5SC60DV N A 6900 N A 714 48oz F5MC72DV N A 7450 N A 690 48oz F5PC72DV N A 7450 N A 1200 48oz F5SC72DV N A...

Страница 14: ...om End Front Of Unit J Junction Box R Refrigeration Lines 0 25 Liquid 0 37 Suction D 0 50 I D Drain R D J 3 75 10cm 3 75 10cm F5 Typical Mechanical Access Plan View F15 REMOTE MODELS 1 75 4cm 1 00 2 5cm C Front Of Unit J Junction Box R Refrigeration Lines 0 25 Liquid 0 37 Suction D 0 50 I D Drain R D D J 3 75 10cm 30 00 76cm 3 75 10cm F15 Typical Mechanical Access Plan View ...

Страница 15: ...quipment nWarning Damp or wet hands may stick to cold surfaces nWarning Maximum weight for shelves is 75 pounds Overloading shelves can damage equipment or cause bodily injury nWarning Do not block the supply and return air grills or the air space around the air grills Keep plastic wrappings paper labels etc from being airborne and lodging in the grills Failure to keep the air grills clear will re...

Страница 16: ...r fan as well as the evaporator fan will remain off until this initial defrost is complete This initial defrost cycle may take up to 35 minutes to complete 3 The display will continue to read dEF for an additional 30 minutes while the cooling cycle cools the box to the set temperature 4 Then the digital thermostat will display box temperature 5 The temperature control will cycle the compressor eva...

Страница 17: ...ay Operation V V Press upper or lower right button Display show actual set point blinking If buttons untouched for 3 seconds returns to normal Increase set point by pressing upper button Max value depends on parameters in control Decrease set point by pressing lower button Min value depends on parameters in control If buttons untouched for 3 seconds returns to normal and stores new set point Press...

Страница 18: ... device Under severe overloading conditions or in the event of a condenser fan failure or a plugged or blocked condenser this device may shut down the refrigeration system This device will automatically reset but determining the cause of the high pressure condition should be investigated by a qualified refrigeration technician Caution In attempting to adjust the pressure control you can do damage ...

Страница 19: ...sh the stand by button lower left button to enter into the display menu 5 Scroll to CFu using the up down arrows and push the stand by button lower left button to enter the display unit menu 6 F should be displayed indicating Fahrenheit Use the down arrow to change it to C for Celsius and hit the stand by button lower left button to enter the change 7 Push the defrost button upper left button to m...

Страница 20: ...d condenser this device may shut down the refrigeration system This device will automatically reset but determining the cause of the high pressure condition should be investigated by a qualified refrigeration technician Caution In attempting to adjust the pressure control you can do damage to your unit Please contact KitchenCare 1 844 724 2273 or your local service agent Delfield is not responsibl...

Страница 21: ...se sharp objects or tools to remove ice or frost Do not use mechanical devices or other means to accelerate the defrosting process Caution Maintenance and servicing work other than cleaning as described in this manual must be done by an authorized service personnel General Cleaning nWarning When using cleaning fluids or chemicals rubber gloves and eye protection and or face shield must be worn Cau...

Страница 22: ...ces with a damp cloth rinsed in water to remove dust and dirt from the outside of the unit Always rub with the grain of the stainless steel to avoid marring the finish If a greasy residue persists use a damp cloth rinsed in a mild dish soap and water solution Wipe dry with a clean soft cloth Never use steel wool or abrasive pads for cleaning Never use chlorinated citrus based or abrasive cleaners ...

Страница 23: ...eavy use doors the hinges may become loose If this happens tighten the screws that mount the hinge brackets to the frame of the unit Loose or sagging doors can cause the hinges to pull out of the frame which may damage both the doors and the hinges In some cases this may require qualified service agents or maintenance personnel to perform repairs SLIDING DOORS Standard With Door Lock Clean the tra...

Страница 24: ...7 Welbilt provides the world s top chefs and premier chain operators or growing independents with industry leading equipment and solutions Our cutting edge designs and lean manufacturing tactics are powered by deep knowledge operator insights and culinary expertise All of our products are backed by KitchenCare our aftermarket repair and parts service CLEVELAND CONVOTHERM DELFIELD FITKITCHEN FRYMAS...