HOST CONFIGURATION STRINGS
149
Code 39
disable Code 39 family
AB0
Standard
no check digit control
AB11
check digit control and transmission
AB12
check digit control without transmission
AB13
Full ASCII
no check digit control
AB21
check digit control and transmission
AB22
check digit control without transmission
AB23
CIP
39
AB3
Code
32
AB4
code
length
AB*
xxxx
2/5
disable Code 2/5 family
AC0
Interleaved 2/5
no check digit control
AC11
xxxx
check digit control and transmission
AC12
xxxx
check digit control without transmission
AC13
xxxx
Normal 2/5 5 bars
no check digit control
AC21
xxxx
check digit control and transmission
AC22
xxxx
check digit control without transmission
AC23
xxxx
Industrial 2/5 (IATA)
no check digit control
AC31
xxxx
check digit control and transmission
AC32
xxxx
check digit control without transmission
AC33
xxxx
Matrix 2/5 3 bars
no check digit control
AC41
xxxx
check digit control and transmission
AC42
xxxx
check digit control without transmission
AC43
xxxx
CIP/HR
AC5
xxxx
= ASCII numbers that define the code length where:
•
First 2 digits = minimum acceptable code length.
•
Second 2 digits = maximum acceptable code length.
The minimum code length must always be less than or equal to the maximum.
The maximum code length for all codes is 99 characters:
Examples:
0132 = variable length from 1 to 32 digits in the code.
1010 = 10 digit code length only.
Содержание DelfiScan M80
Страница 1: ...DelfiScan M80 Programming Manual...
Страница 3: ......
Страница 14: ...INSTALLATION 7 2 8 PEN EMULATION CONNECTION 2 9 SINGLE READER LAYOUT...
Страница 22: ...CONFIGURATION 15 WEDGE CONTINUED DIGITAL TERMINALS VT2xx VT3xx VT4xx CP512 u...
Страница 39: ...Enter Configuration Exit and Save Configuration USB KBD 32 USB KEYBOARD SPEED Normal UT10c Fast UT01d...
Страница 162: ...CODE IDENTIFIER TABLE tu RSS Limited RSS 14 Linear and Stacked vw uv...