16. The manual valve should not be used to adjust gas flow.
17. All components must be securely mounted with screws, bolts, etc., within the machine.
NOTE: The trigger on the gun must be pulled to allow antifreeze to pass through the coils, and then
the trigger must be released to allow the antifreeze to pass through the bypass line.
18. Turn the key switch to the “OFF” position and close the metering valve.
19. Store the machine in a dry building.
It is critical that the oil in your machine be checked regularly. To check the oil follow this procedure:
1. Locate the oil dipstick in the plug on the top of the pump.
2. Turn the oil plug counterclockwise.
3. Wipe the dipstick with a clean cloth.
4. Put the dipstick in the hole without turning it.
5. Remove the dipstick. If the oil is below the notch, add SAE 30 weight, non-detergent oil.
6. Put the dipstick in the hole.
7. Turn the plug clockwise until it stops.
NOTE: Change the oil after the first 50 hours of use and then after every 500 hours of use.
The following warning applies to installations using L.P., Propane Gas:
WARNING:
T
o avoid possible injury, fire and explosion, please read and follow these precautions and
all instructions on this machine before lighting the pilot. This machine uses L.P. (Pro-
pane) gas which is heavier than air and will remain at
floor level
if there is a leak. Before
lighting, sniff at
floor level. If you smell gas
, follow these rules:
1. Get all people out of building.
2.
DO NOT
light matches.
DO NOT
turn electric lights or switches on or off in area.
DO NOT
use an
electric fan to remove gas from area.
3. Shut off gas at L.P. tank outside of building.
4. Telephone gas company and fire department. Ask instructions. Before hanging up, give your name,
address, and phone number.
DO NOT
go back into the building. If help is coming wait for them to
arrive. If your L.P. tank runs out of fuel, turn off gas at the machine. After L.P. tank is refilled, ma-
chine must be re-lit according to manufacturer's instructions. If the gas control has been exposed to
WATER
in any way,
DO NOT
try to use it. It must be replaced.
DO
NOT
attempt repair on gas valve
. It must be replaced.
DO NOT
attempt repair on gas control or machine. Call an authorized Delco
distributor for service. Tampering is
DANGEROUS
and voids all warranties.
18. Do not short gas valve terminals. This may burn out the controls.
19. Make certain all wiring connections are tight. The spark ignitor and electrode connection to the ignition
control must be tight, or damage to the unit may result.
Содержание 1500 - 5 NG 091
Страница 19: ...9 1 e g a P P L G N 5 0 0 0 2 4 0 0 0 3 Delco Eliminator 2000 4 1000 5 NG LP 1 3 Phase Drawing 1 Machine Layout...
Страница 20: ...P L G N 5 0 0 0 2 4 0 0 0 3 0 2 e g a P Delco Eliminator 2000 4 1000 5 NG LP 1 3 Phase Drawing 2...
Страница 22: ...P L G N 5 0 0 0 2 4 0 0 0 3 2 2 e g a P Delco Eliminator 2000 4 1000 5 NG LP 1 3 Phase...
Страница 24: ...P L G N 5 0 0 0 2 4 0 0 0 3 4 2 e g a P Delco Eliminator 2000 4 1000 5 NG LP 1 3 Phase Drawing 4...
Страница 29: ...DELCO Eliminator 2000 4 NG LP 1500 5 NG LP Single Phase Electrical Schematic...
Страница 30: ...Delco Eliminator 2000 4 1000 5 NG LP 3 Phase with shut down timer Electrical Schematic 2 2010 Addendum...