Check pipe sizing

to avoid water hammer, pressure and flow rate

losses. (see our brochure or web site).

• 

Protect hydraulic installation

by general filters and pressure

regulator in order to reduce maintenance frequency.  

• 

A service valve

should be fitted in close proximity to sanitary taps to

simplify maintenance.

FLOW RATE ADJUSTMENT

In order to adapt flow rate to the existing pressure, you have 
to adjust flow rate on stop cock.

CLEANING AND SERVICING

• 

Chrome cleaning

: Clean the plated chrome with mild soap 

and water, with a soft cloth. 
DO NOT USE ABRASIVE or chlorin cleaners.

• 

Risk of freezing :

Flush out the supply, and push on several 

times to flush out the valve.In case of freezing, remove the

complete cartridge containing the mechanism and store it. 

Attention : never grease the internal mechanism.

GB

GB

Separate stop cock

Integrated stop cock :
Adjust flow rate on stop screw of the valve

Содержание TEMPOFLUX

Страница 1: ...dice A 26 06 07 NOTICE D INSTALLATION T E M P O F L U X DELABIE S C S 18 rue du Mar chal Foch 80130 FRIVILLE Tel 03 22 60 22 74 Fax 03 22 30 31 07 e mail sav delabie fr Robinet temporis 3 4 pour chass...

Страница 2: ...e raccordement alimentation eau 761900 705028 500 mm au dessus de la cuvette 761900 761627 36 42 74 3 4 25 53 85 3 5 53 21 80 80 50 55 63 220x170 38 25 36 43 68 3 4 25 54 79 7 49 24 80 80 195 38 25 55...

Страница 3: ...sse 400 mm minimum avec un rayon du coude de 50 mm minimum TEMPOFLUX ENCASTRE Utiliser le gabarit pour r servation d encastrement mural H 170 x L 145 x P 90 Profondeur r glable 80 105 mm fig 1 Visser...

Страница 4: ...r le d bit la pression existante ce r glage s effectue sur le robinet d arr t situ en amont du robinet de chasse Robinet d arr t int gr R gler le d bit sur la vis du robinet NETTOYAGE ENTRETIEN Nettoy...

Страница 5: ...une pointe non m tallique Fig 2 Goutte goutte ou filet d eau Nettoyer le si ge du corps du robinet et v rifier nettoyer le joint de si ge ou le remplacer s il est endommag Fig 2 Refoulement d eau au n...

Страница 6: ...A 26 06 07 INSTALLATION USER GUIDE T E M P O F L U X DELABIE S C S 18 rue du Mar chal Foch 80130 FRIVILLE FRANCE Tel 33 3 22 60 22 74 Fax 33 3 22 30 31 07 e mail sav delabie fr Self closing WC flush...

Страница 7: ...water outlet Water inlet connection 761900 705028 500 mm 761900 761627 36 42 74 3 4 25 53 85 3 5 53 21 80 80 50 55 63 220x170 38 25 36 43 68 3 4 25 54 79 7 49 24 80 80 195 38 25 55 63 76 mont M3 4 11...

Страница 8: ...ent minimum Recommended dynamic pressure 1 to 5 bar RECESSED TEMPOFLUX Use the recessing box master for wall fitting H 170 x L 145 x D 90 Adjustable Depth 80 105 mm fig 1 Screw the flush valve on to t...

Страница 9: ...adapt flow rate to the existing pressure you have to adjust flow rate on stop cock CLEANING AND SERVICING Chrome cleaning Clean the plated chrome with mild soap and water with a soft cloth DO NOT USE...

Страница 10: ...is damaged Fig 5 Water discharge from integrated vacuum breaker Reduce water pressure Flush tube must not be in full lock on WC pan and should have a 50 bent Lack no flushing Too low dynamic pressure...

Отзывы: