Delabie TEMPOFLUX Скачать руководство пользователя страница 8

fig. 2

fig. 3

fig. 4

INSTALLATION

• 

Flush out

thoroughly supply pipes BEFORE connection to the

flush valve.

• In straight type (inline connection) ensure that water circulation

is in direction of the 

arrow marked on the body

.

• 

Push on several times

to stabilise the timer.

• Push button height / WC pan : 500 mm. minimum
• Flush tube height : 400 mm. minimum with 50° bent minimum.
• Recommended dynamic pressure : 1 to 5 bar

RECESSED TEMPOFLUX : 

• Use the recessing box master for wall fitting :

H.170 x L.145 x D.90 Adjustable Depth : 80 à 105 mm. 

(fig.1)

• Screw the flush valve on to the wall

(fig.2)

• Connect water supply ø20/22, and install the PVC flush

tube ø32/26 or 32x3, or use the flush tube ref.769400).

Tighten union nuts on water supply and flush tube. 

(fig.3)

• Push the button to start water flushing, and adjust the flow

rate on adjustable screw during flushing

(fig.3)

.

• Install the wall plate and its ring, with stop screw.

(fig.4)

GB

Содержание TEMPOFLUX

Страница 1: ...dice A 26 06 07 NOTICE D INSTALLATION T E M P O F L U X DELABIE S C S 18 rue du Mar chal Foch 80130 FRIVILLE Tel 03 22 60 22 74 Fax 03 22 30 31 07 e mail sav delabie fr Robinet temporis 3 4 pour chass...

Страница 2: ...e raccordement alimentation eau 761900 705028 500 mm au dessus de la cuvette 761900 761627 36 42 74 3 4 25 53 85 3 5 53 21 80 80 50 55 63 220x170 38 25 36 43 68 3 4 25 54 79 7 49 24 80 80 195 38 25 55...

Страница 3: ...sse 400 mm minimum avec un rayon du coude de 50 mm minimum TEMPOFLUX ENCASTRE Utiliser le gabarit pour r servation d encastrement mural H 170 x L 145 x P 90 Profondeur r glable 80 105 mm fig 1 Visser...

Страница 4: ...r le d bit la pression existante ce r glage s effectue sur le robinet d arr t situ en amont du robinet de chasse Robinet d arr t int gr R gler le d bit sur la vis du robinet NETTOYAGE ENTRETIEN Nettoy...

Страница 5: ...une pointe non m tallique Fig 2 Goutte goutte ou filet d eau Nettoyer le si ge du corps du robinet et v rifier nettoyer le joint de si ge ou le remplacer s il est endommag Fig 2 Refoulement d eau au n...

Страница 6: ...A 26 06 07 INSTALLATION USER GUIDE T E M P O F L U X DELABIE S C S 18 rue du Mar chal Foch 80130 FRIVILLE FRANCE Tel 33 3 22 60 22 74 Fax 33 3 22 30 31 07 e mail sav delabie fr Self closing WC flush...

Страница 7: ...water outlet Water inlet connection 761900 705028 500 mm 761900 761627 36 42 74 3 4 25 53 85 3 5 53 21 80 80 50 55 63 220x170 38 25 36 43 68 3 4 25 54 79 7 49 24 80 80 195 38 25 55 63 76 mont M3 4 11...

Страница 8: ...ent minimum Recommended dynamic pressure 1 to 5 bar RECESSED TEMPOFLUX Use the recessing box master for wall fitting H 170 x L 145 x D 90 Adjustable Depth 80 105 mm fig 1 Screw the flush valve on to t...

Страница 9: ...adapt flow rate to the existing pressure you have to adjust flow rate on stop cock CLEANING AND SERVICING Chrome cleaning Clean the plated chrome with mild soap and water with a soft cloth DO NOT USE...

Страница 10: ...is damaged Fig 5 Water discharge from integrated vacuum breaker Reduce water pressure Flush tube must not be in full lock on WC pan and should have a 50 bent Lack no flushing Too low dynamic pressure...

Отзывы: