32 mm
Calibrated groove
Delay case
Seat washer
Lip seal
Piston
MAINTENANCE
•
Too long self-closing delay or continuous flushing
:
Clean the delay case with a dry cloth, and the calibrated timer
groove with a non metallic point
(Fig 5)
•
Drip or leak
:
Clean the seat washer, and check/clean the seat joint,
or replace it if it is damaged.
(Fig 5)
•
Water discharge from integrated vacuum-breaker
:
Reduce water pressure. Flush tube must not be in full lock on
WC pan and should have a 50° bent.
•
Lack/no flushing
:
Too low dynamic pressure or insufficient size of pipe.
To remove the mechanism, unscrew the cartridge with a 32mm
A.F. spanner (Fig 1) or 32 mm / 7 mm thick. for recessed valves.
GB
International technical support service
:
Phone
:
+33.3.22.60.22.74
e.mail
For Douglas Delabie UK market only : Phone
: 01491 824449
e.mail