OPERATION
• Stable mixed water temperatures.
• Anti-scalding safety: Hot Water supply shuts off if the Cold Water supply fails.
TECHNICAL FEATURES
•
733015: 20 lpm at 3 bar
, for 2 - 7 valves depending on the flow rate of the valve
(NB: TEMPOMATIC, TEMPOSTOP… at 3 lpm).
•
733020: 25 lpm at 3 bar
, for 2 - 10 valves depending on the flow rate of the valve
(NB: TEMPOMATIC, TEMPOSTOP… at 3 lpm).
•
Integrated non-return valves and filters.
• Pre-set at 38°C (HW and CW pressure 3 bar).
INSTALLATION
• Recommended pressure: 1 - 5 bar.
• Hot Water supply temperature: 55 - 85°C (the temperature differential between the hot water
and the cold water must be at least 50°C).
• Cold Water supply temperature: 5 - 20°C.
• Balance the pressure between HW / CW (ΔP<1 bar)
•
Do not remove the filters and non-return valves incorporated in the water inlets.
• Connect the water inlets (Hot Water on the red side – Cold Water on the blue side).
• PREMIX Compact can be installed in any position (
fig. B and C
).
EN
CHEMICAL AND THERMAL SHOCKS
This product has been designed to withstand both thermal and chemical shocks in line with current
regulations.
REMEMBER
•
Our mixers must be installed by professional installers
in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
•
Sizing the pipes correctly
will avoid problems of flow rate, pressure loss and water hammer
(see calculation table in our brochure and online at www.delabie.com).
•
Protect the installation
with filters, water hammer absorbers and pressure reducers to reduce
the frequency of maintenance (recommended pressure from 1 to 5 bar (100 to 500 kPa) maximum).
•
Install stopcocks
close to the mixerto facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should
be checked at least once a year, and more frequently if necessary.