13

CLEANING the DISPERSION STONE

Periodically, the dispersion stone may clog up with mineral deposits reduc-

ing the amount of ozone flow through the stone. The stone will appear a 

darker color. 

Disconnect Power

 and remove the dispersion stone.Soak it 

in lemon juice or vinegar for a few hours to overnight until the discoloration 

is gone and the dispersion stone is a uniform color. Rinse the dispersion 

stone thoroughly with fresh water. Reinstall the dispersion stone. 

NOTE:

 Sometimes the stain will be permanent; if ozone bubbles still flow 

from the dispersion stone the stain will not affect operation.

CHANGING the PUMP FILTER

The Portable Purifier Pump filter may require cleaning or replacing up to 

every six months depending on the purifier’s exposure. 

Disconnect Power 

before servicing the unit. 

The filter can be removed and replaced by ac-

cessing it through the hole in the back of the purifier with a pair of tweezers 

or pliers. If there is no filter access hole on the back of your purifier, remove 

the pump by removing the two mounting screws on the back of the unit. Be 

careful not to over-tighten the screws when re-mounting the pump.

UNIT SPECIFICATIONS

        

Electrical Specs:

              120 vac, .5 amps, 60 watts

        

Cabinet:

                            Aluminum, powder coated finish

        

Unit Dimensions:

              9H X 13.5W X 3.2D

        

Unit Weight:

                     6 lbs

        

Shipping Weight:

              7 lbs

        

Operating Temperature:   

35

F to 100

F

        

Compressor Provides:

     5 scfh @ 2 psi

PARTS LIST

 

 

Replacement Lamp 

 

9-0488

 

 

Ballast   

 

 

5-0240

 

 

Ozone Supply Tubing   

7-0723

 

 

Dispersion Stone 

 

7-0785

 

 

Suction Cup 

 

 

7-0839

 

 

Pump   

 

 

5-0782

 

 

Pump Filter 

 

 

7-0877

 

 

Ball Chain 

 

 

8-0304

 

 

Ozone Supply Check Valve 

7-1004

 

 

Thru-Wall Disperser Assembly  9-0152

 

 

Thru-Wall Disperser Element  7-0422

Содержание Z0-151

Страница 1: ...INSTALLATION OPERATIONS MANUAL FOR DELZONE Z0 151 PORTABLE PURIFIER MANUFACTURED BY 3428 Bullock Lane San Luis Obispo CA 93401 800 676 1335 4 0252 Rev B 050904...

Страница 2: ...ne 9 Do not expose your pets to ozone 10 When used for water purification make sure that a If the electrical connection of the ZO 151 Portable Purifier is made directly to a spas electrical system be...

Страница 3: ...t of Boats and RVs 7 Automobile Odors 7 Treatment of Fruits and Vegetables 8 Treatment of Food and Cooking Utensils 8 Portable Water Treatment 8 PERMANENT APPLICATIONS Spas and Pools 9 Thru Wall Dispe...

Страница 4: ...Nice France where it was used to purify drinking water Today more than thirty countries use ozone systems to purify drinking water In fact Los Angeles has one of the larg est ozone water treatment pla...

Страница 5: ...unit and its components The unit should include ZO 151 PORTABLE PURIFIER UNIT OZONE SUPPLY TUBING 15 FEET OZONE DISPERSION STONE SUCTION CUP 4 BALL CHAIN 4 ADHESIVE RUBBER FEET Connect ozone supply tu...

Страница 6: ...the dispersion stone Locate the dispersion stone as high and as far from other objects as possible Figure 1 for example Turn on the Portable Purifier and or set the timer and leave the room Allow the...

Страница 7: ...10 X 10 60 minutes BEDROOM Unpleasant odors 17 X 18 60 minutes Cigarette odors CLOSET AREA Shoes clothes with odors 4 X 4 45 minutes CLOTHES Mildew Musty locate dispersion 15 minutes stone near garme...

Страница 8: ...odors 18 24 60 minutes Cigarette food odors 30 32 70 minutes Cigarette food odors 35 40 75 minutes Soured foods locate 15 minutes dispersion stone at bottom of garbage can BOAT INTERIOR Dust stale ai...

Страница 9: ...treat in clean water with ozone for fifteen minutes PORTABLE WATER TREATMENT The ZO 151 Portable Purifier is specifically designed to purify water in emergency storage spas bathtubs fountains and wadi...

Страница 10: ...feet from the spa or water enclosure and at twelve inches above the maximum water level Ensure that the location is out of the reach of children or anyone in the water 2 To mount the ZO 151 Portable...

Страница 11: ...ough edges in the hole and remove any drilling debris from the bottom of the spa Figure 3 Thru Wall Disperser Installation Diagram 2 Place the supplied gasket on the threaded side of the thru wall dis...

Страница 12: ...amp cartridge connection loose 5A Reconnect 6 Lamp burnt out 6A Replace lamp SYMPTOM Red indicator light OFF air pump working but no ozone bubbles in spa PROBABLE CAUSE CORRECTIVE ACTION 7 Leak in sys...

Страница 13: ...t strain on wires connecting cover components 4 Separate the finned aluminum lamp cartridge from its mounting bracket It may require the use of a screwdriver to pry the unit loose as these clamps are...

Страница 14: ...the purifier s exposure Disconnect Power before servicing the unit The filter can be removed and replaced by ac cessing it through the hole in the back of the purifier with a pair of tweezers or plie...

Страница 15: ...ARE HEREBY DISCLAIMED AND e DEL Ozone SHALL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR LOSS OF USE OF SUCH PRODUCTS LOST PROFITS DIRECT DAMAGES INDIRECT DAM AGES CONSEQUENTIAL DAMAGES AND OR incidental...

Страница 16: ...15 Copyright 2004 DEL Ozone...

Отзывы: