13
CLEANING the DISPERSION STONE
Periodically, the dispersion stone may clog up with mineral deposits reduc-
ing the amount of ozone flow through the stone. The stone will appear a
darker color.
Disconnect Power
and remove the dispersion stone.Soak it
in lemon juice or vinegar for a few hours to overnight until the discoloration
is gone and the dispersion stone is a uniform color. Rinse the dispersion
stone thoroughly with fresh water. Reinstall the dispersion stone.
NOTE:
Sometimes the stain will be permanent; if ozone bubbles still flow
from the dispersion stone the stain will not affect operation.
CHANGING the PUMP FILTER
The Portable Purifier Pump filter may require cleaning or replacing up to
every six months depending on the purifier’s exposure.
Disconnect Power
before servicing the unit.
The filter can be removed and replaced by ac-
cessing it through the hole in the back of the purifier with a pair of tweezers
or pliers. If there is no filter access hole on the back of your purifier, remove
the pump by removing the two mounting screws on the back of the unit. Be
careful not to over-tighten the screws when re-mounting the pump.
UNIT SPECIFICATIONS
Electrical Specs:
120 vac, .5 amps, 60 watts
Cabinet:
Aluminum, powder coated finish
Unit Dimensions:
9H X 13.5W X 3.2D
Unit Weight:
6 lbs
Shipping Weight:
7 lbs
Operating Temperature:
35
0
F to 100
0
F
Compressor Provides:
5 scfh @ 2 psi
PARTS LIST
Replacement Lamp
9-0488
Ballast
5-0240
Ozone Supply Tubing
7-0723
Dispersion Stone
7-0785
Suction Cup
7-0839
Pump
5-0782
Pump Filter
7-0877
Ball Chain
8-0304
Ozone Supply Check Valve
7-1004
Thru-Wall Disperser Assembly 9-0152
Thru-Wall Disperser Element 7-0422
Содержание Z0-151