TROUBLE SHOOTING
There are four areas to check to determine the location of any problem:
1. The green indicator light should remain ON during operation
2. The red indicator light should remain OFF during operating
3. Presence of ozone bubbles in the water
4. The condition of the water
SYMPTOM:
Green indicator light OFF - air pump not working
PROBABLE CAUSE CORRECTIVE ACTION
1. No power to unit 1A. Check power source and cord
2. Tripped circuit breaker 2A. Reset circuit breaker
3. G.F.C.I. tripped 3A. Reset G.F.C.I.
4. Defective electrical system 4A. Return for service/repair
SYMPTOM:
Red and green indicator lights ON - air pump working
PROBABLE CAUSE CORRECTIVE ACTION
5. Lamp cartridge connection loose 5A. Reconnect
6. Lamp burnt out 6A. Replace lamp
SYMPTOM:
Red indicator light OFF, air pump working but no ozone
bubbles in spa
PROBABLE CAUSE CORRECTIVE ACTION
7. Leak in system 7A. Check all tubing connections
8. Tubing is kinked or crimped 8A. Check all tubing and unkink
9. Dispersal element plugged 9A. Clean or replace dispersal
element
10. Defective electrical system 10A. Return to dealer for service
SYMPTOM:
Everything works correctly, but water is dirty
PROBABLE CAUSE CORRECTIVE ACTION
11. Excessive bather load 11A. If the extra high bather load
is not unusual, continue 24 hr.
operation and begin program
of adding a small amount of
chlorine, bromine
shock treatment.
12. pH not balanced 12A. Adjust pH to 7.2 to 7.8
13. Total alkalinity incorrect 13A. Adjust total alkalinity to
80 -150 PPM
14. Dirty, loose, or cracked filter 14A. Service filter.