background image

4-0026 Rev.F

ECT-2 and ECT-4 
Installation & Operations Manual

Total Eclipse

Содержание Total Eclipse Series

Страница 1: ...4 0026 Rev F ECT 2 and ECT 4 Installation Operations Manual Total Eclipse...

Страница 2: ...of pool water using nonmetallic tubing It is highly recommended that the ozone generator be installed at least one 1 foot above the water level to prevent water from contacting electrical equipment I...

Страница 3: ...pecifications 1 SECTION 2 Installation Operation 2A Installation 1 2B Operation 3 2C Maintenance 4 SECTION 3 Trouble Shooting 8 SECTION 4 Replacement Parts Ordering Information 4A Ordering Information...

Страница 4: ...w switch and check valve for protection of pump and ozone modules SECTION 2 Installation Operation 2A Installation The most common pool and pool spa configurations are discussed in this manual For add...

Страница 5: ...s highly recommended Bubble formation and gurgling may occur otherwise NOTE Air bubbles in the system can be removed by installing a DEL MDV 20 Contact your local dealer or visit DEL s website at www...

Страница 6: ...ssary If no winterizing will take place unions are still included to facilitate unit removal if necessary 2B Operation Once the Total Eclipse has been properly installed simply plug the unit into a 12...

Страница 7: ...ng the Wire Connector apart from the wire harness 7 Reverse process to install new Ozone Module 2C 2 Check Valve Replacement The ozone check valve should be replaced annually to avoid back flooding is...

Страница 8: ...for Infloor Cleaning System 2 Even when the ICS is not operating bubbles from the ozone generator will escape through the ICS head 5 Total Eclipse Installation Operations Manual Common Installation D...

Страница 9: ...t using an eyeball fitting or reducer nozzle at the point of entry ie the wall This will help to break up the bubbles and push them further out preventing any possible discoloration to the pool wall N...

Страница 10: ...nits Ozone Check Valve Ozone Injector Expansion Fitting Water In Water Out Power Indicator Light No Flow Indicator Light Air Filter cap and cotton filter one per ozone module Ozone Module Manifold bla...

Страница 11: ...a new sanitation device like the Total Eclipse will destroy a great deal of contaminants in the water and leave them to be filtered out Therefore you many find it necessary to clean your filter to un...

Страница 12: ...d any large bubbles being trapped and released plumb with a single 3 4 line independently returned to the bottom of the pool In addition keep all pipe runs to the pool straight and level using a minim...

Страница 13: ...10 APPENDIX A Warranty APPENDIX A Warranty...

Страница 14: ...egligence accident fire flood repair materials and or unauthorized accessories c Any such products installed without regard to required local codes and accepted trade practices d Damage to unit caused...

Страница 15: ......

Страница 16: ...3580 Sueldo Street San Luis Obispo CA 93401 800 676 1335 o3info delozone com www delozone com EPA Estab No 071472 CA 001...

Отзывы: