MCD
Installation & Operations Manual
SECTION 1 Installation Instructions
1. How the DEL Spa Ozone Generator Works
DEL Ozone Generators produce ozone gas which is introduced to
the spa water through suction created by the spa. Tubing is used
to connect the Ozone Generator to an injector or a vacuum port
provided by the spa manufacturer. The injector or port are vacuum
sources used to pull the ozone gas out of the Ozone Generator
and into the water. At no time should water come in contact with
the Ozone Generator. To protect the Ozone Generator from water
traveling backwards through the tubing connection, the unit must
be mounted and plumbed as described in this manual.
2. Installation Parts
Common Installation Parts for MCD Spa Ozone Generators:
• One (1) Installation Manual (4-2308-01)
• One (1) check valve (7-1140-01)
• Five (5) feet of tubing (7-0075)
• Four (4) hose clamps (2-0078)
• Two (2) screws (2-0278) for mounting
3. Installation Tools and Materials
a. Phillips Screwdriver
b. Pliers
c. Scissors
4. Unit Assembly
All models are pre-assembled and ready to install.
5. Mounting
a. Mount the Ozone Generator as high as possible within the spa’s
protected equipment area.
b. Screws are provided for mounting but may not be appropriate for
all surfaces. Substitute proper mounting hardware as required.
Use the mounting features provided on the Ozone Generator.
6. Plumbing – Vacuum System (refer to Figure 1)
a. Most spas are factory equipped with an ozone injector, like the
one shown in Fig. 1. Review your Spa’s Installation Manual to
identify the correct ozone connection location.