Содержание CDS-16

Страница 1: ...OZONE GENERATORS FOR SPAS INSTALLATION OPERATION MANUAL For Models SpaEclipse SpaEclipse Dual Voltage CDS 16 ZO 300 302 ZO 301 Platinum 4 1223 01 Rev B EPA Estab No 071472 CA 001...

Страница 2: ...nd Platinum ozone generator units to allow the connection of a minimum No 8 AWG 8 4 mm2 solid bonding conductor wire between this point and any metal equipment metal enclosure of electrical equipment...

Страница 3: ...lation Parts 4 3 Installation Tools and Materials 4 4 Unit Assembly 4 5 Mounting 6 6 Plumbing Vacuum System 6 7 Plumbing Ozone Generator 6 8 Electrical 7 9 Operation 7 10 Installation Complete 8 11 Ma...

Страница 4: ...1 ONE check valve 7 1140 01 FIVE feet of tubing 7 0075 FOUR hose clamps 2 0078 TWO screws 2 0078 for mounting c Installation Parts specific to SpaEclipse Dual Voltage ONE Voltage Selector Switch Cover...

Страница 5: ...te Lamp Cartridge Figure 1 Assembly of ZO 300 or ZO 302 Cartridge Figure 2 Ozone Generator Models CDS 16 SpaEclipse Dual Voltage ZO 300 302 ZO 301 Platinum Power Supply Bonding Plate Lamp Cartridge Oz...

Страница 6: ...her models use the mounting features provided on the Ozone Generator 6 Plumbing Vacuum System refer to Figure 4 a Most spas are factory equipped with an ozone injector or vacuum port like the one show...

Страница 7: ...age 9 Operation a With the spa filled to the proper level run the spa controller through several cycles b Verify that the Ozone Generator turns on and off as required by the controller i For the ZO 30...

Страница 8: ...e instruction sheet b In between Renewal Kit replacement years change the ozone check valve 7 1140 01 and Ozone Tubing 7 0075 c Although Platinum and ZO 301 do not have serviceable ozone components oz...

Страница 9: ...SYMPTOM The green LED not lit on Platinum No power to the ozonator Check the electrical connections and then the fuse PROBABLE CAUSE 1 Unit and pump not operating long enough 2 Total alkalinity not co...