Quick Start Guide
Safety
Follow the safety guidelines. DO NOT PROCEED WITHOUT UNDERSTANDING
AND OBSERVING THESE GUIDELINES.
Requirements
Make sure the PCX-7500:
•
Is connected with the proper cables and termination impedance
•
Is powered up
•
Has all faults cleared
•
Has the rear enable and keyswitch enabled (the proper icons will be green
when enabled)
Controlling the PCX-7500 from the front panel
1. Disable the PCX-7500
¾
The
Enable
button on the front panel glows green if the PCX-7500 is
enabled. Press the button to disable. The green light goes out.
2. Set the output current
¾
Press the
Output
button on the touch screen.
¾
Press the encoder knob to set the resolution to x0.1, x1.0, or x10.0.
¾
Turn the encoder knob to set the output current from 10.0 A to 450.0 A.
¾
Press the
Done
button.
3. Set the trigger to internal or external
¾
Press the
Trigger
button on the touch screen.
¾
Press the
Internal
or
External
button to select the trigger.
4. Set the internal pulse trigger frequency
¾
Press the
Frequency
icon on the touch screen.
¾
Press the encoder knob to set the resolution to x1, x10, x100, x500,
x1000, or x5000.
¾
Turn the encoder knob to set the frequency from 8 Hz to 10,000 Hz.
¾
Press the
Done
icon.