![DEI PCX-7500 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/dei/pcx-7500/pcx-7500_operation-manual_2465163014.webp)
Sync Output
Synchronization pulses for external devices are available at the Sync Output BNC
connector. The sync pulse corresponds to the leading edge of the output current
pulse.
Keyswitch
The keyswitch ON position allows the PCX-7500 output current to be enabled. In
the keyswitch OFF position, the PCX-7500 is disabled.
Rear Panel Features
Current Output
This socket accepts the factory-supplied output cable and is the connection for the
system-generated current pulses. DO NOT TOUCH any part of this cable while the
PCX-7500 is powered up. Please review the Safety section.
Note:
The absence of a properly installed output cable disables the output and
creates an output enable fault.
Rear Enable
This connector accepts either an external dry contact closure or the factory-supplied
shorting BNC plug. Closed contacts or the use of the shorting plug enables the
output. Open contacts or removal of the shorting plug disables the output and
creates a rear enable fault.
USB
Ethernet
RS232
AC
Power
Connector
Current
Output
Power
Switch
Rear
Enable
Voltage
Monitor