12
Connect the appropriately marked tank connections firmly, tightly and in a de-energised state using the supplied PVC hoses and
the preassembled PP hose nozzles.
Fit the mounting bracket of the air compressor in direct proximity to the greywater buffer tank/BMT-unit on a supporting concrete
wall using the supplied assembly accessories. Please ensure that all four feet of the air compressor are placed solidly on the
bracket.
Connection
Connection
width at tank
Material
Colour
Air compressor
¾“ mal thread
PVC-flex tube ø19 mm
Red
Filtrate effluent
¾“ male thread
PVC-flex tube ø13 mm
blue
Figure 5: Connect hose lines for ventilation and filtrate
When installing the PVC hoses, ensure that there are no constrictions/kinks, which can prevent the free flow of
water and air.
The greywater buffer tank/BMT unit must not be higher than the process water storage tank when filtrate inflow
shall be provided by gravity.
The air compressor must be fitted above the max. water level of the BMT unit.
5.5.
Air compressor and filtrate lines