Unless there is an abnormal 

condition, do not attempt to remove 

the gas burner taps. You must call 

an authorised service agent if it is 

necessary to change the taps. 

New injectors have their position 

marked on their packing or refer to 

the Injector table. 

 

Reduced gas flow rate setting for taps 

1. Ignite the burner that is to be adjusted and 

turn the knob to the reduced position. 

2. Remove the knob from the gas tap. 

3. Use an appropriately sized screwdriver to 

adjust the flow rate adjustment screw. For 

LPG (Butane - Propane) turn the screw 

clockwise. For natural gas, you should 

turn the screw 

counter-clockwise 

once. 

The normal length of a straight flame in 

the reduced position should be 6-7 mm 

4. If the flame is higher than the desired 

position, turn the screw clockwise. If it is 

smaller turn anticlockwise. 

5. For the last control, bring the burner to 

both the high-flame and reduced positions 

and check whether the flame is on or off. 

  Depending on the type of gas tap used in 

your appliance the adjustment screw 

position may vary. 

Flow rate adjustment screw 

Final check 

1. Open gas supply. 

2. Check gas installations for secure fitting 

and tightness. 

3. Ignite burners and check appearance of 

the flame. 

Gas conversion 

In order to have the appliance's gas type 

changed, all the injectors must be changed 

and the flame adjustment for all valves must 

be set at the reduced flow rate position. 

 

Changing the injectors 

1. Take off burner cap and burner body. 

2. Unscrew injectors by turning them 

counterclockwise. 

3. Fit new injectors. 

4. Check all connections for secure fitting 

and tightness.  

 

The flames should be blue and 

burn smoothly. If the flames 

appear yellowish, check that the 

burner cap is seated correctly or 

clean the burner. Switch off  the 

gas and let burner cool before 

touching it. 

DANGER  Risk  of  explosion  or 

poisoning  by  unprofessional 

installation. 

Gas  conversion 

must  only  be  carried  out  by  a 

registered installer. 

 

DANGER Risk of explosion! 

Before  starting  any  work  on  the 

gas  installation,  shut  off  the  gas 

supply

 

Flame failure device (model dependent) 

2

  Spark plug 

3

  Injector 

4

  Burner 

 

If the gas type of the appliance is 

changed, then the rating plate 

that shows the gas type of the 

unit must also be changed. 

Содержание DHG605

Страница 1: ...Page 1 DHG605 SLIMLINE GAS ELECTRIC HOB Cooking Instruction manual Part number 071006D...

Страница 2: ...n on how to operate and care for your appliance to gain the maximum benefit from it We trust you will enjoy years of trouble free use EXPLANATION OF SYMBOLS Throughout this User Manual the following s...

Страница 3: ...user 11 Electrical connection 12 Gas connection 12 Leakage control 13 Fitting the hob 13 Final check 14 Gas conversion 14 Package information 15 Future transportation 15 Disposing of the old product 1...

Страница 4: ...rview The manufacturer strives for continuous improvement For this reason technical specifications text and illustrations in this manual are subject to change without notice Figures in this manual are...

Страница 5: ...echnical specifications may be changed without prior notice to improve the quality of the appliance Figures in this manual are schematic and may not exactly match your appliance Values stated on the a...

Страница 6: ...ul when using alcoholic drinks in your dishes Alcohol evaporates at high temperatures and may cause a fire since it can ignite when it comes into contact with hot surfaces Do not use the appliance for...

Страница 7: ...chen is well ventilated keep natural ventilation holes open or install a mechanical ventilation device mechanical extractor hood Prolonged intensive use of the appliance may call for additional ventil...

Страница 8: ...of the occupants in the room in which the appliance is installed Intended use This appliance is designed for domestic use Commercial use will void the warranty CAUTION This appliance is for cooking pu...

Страница 9: ...ight min 650 mm Remove packaging materials and transport locks Surfaces synthetic laminates and adhesives used must be heat resistant 100 C minimum The worktop must be aligned and fixed horizontally C...

Страница 10: ...of the mounting cabinet should take account of these characteristics Surfaces and surrounding edges immediately adjacent to the hob should be able to withstand temperatures of up to 100 C without del...

Страница 11: ...ies with SANS 1237 must be used Permanent installation Important information for the user This appliance may only be installed by a registered LP Gas installer All registered installers are issued wit...

Страница 12: ...held responsible for damages arising from procedures carried out by unauthorized persons Plug the power cable into the socket Gas connection DANGER Risk of explosion or poisoning by unprofessional in...

Страница 13: ...order to protect the manifold from being contaminated with debris The manifold protection plug must be removed when the product is installed by the gas installer The red manifold protection plug can b...

Страница 14: ...nt screw position may vary 1 Flow rate adjustment screw Final check 1 Open gas supply 2 Check gas installations for secure fitting and tightness 3 Ignite burners and check appearance of the flame Gas...

Страница 15: ...it Follow the instructions on the carton If you do not have the original carton pack the appliance in bubble wrap or thick cardboard and tape it securely Secure the caps and pan supports with adhesiv...

Страница 16: ...appliance can be hot do not place plastic and aluminum vessels on it Such vessels should not be used to keep foods in either Use flat bottomed saucepans or cooking vessels only Put only the appropria...

Страница 17: ...f the gas valves Gas valves must be controlled from 90 to 210 or 160 according to the gas valve model If flame is set from 0 to 90 the burner will be below the minimum output and may result in a flash...

Страница 18: ...to level P You cannot press to go back to level 0 Continuously holding down button or will increase or decrease the power level Triple zone symbol 3 How to activate the Triple Zone If you want to act...

Страница 19: ...to cool down before you clean it Sugar based foods such as thick cream and syrup must be cleaned promptly without waiting the surface to cool down Otherwise glass ceramic surface may be damaged perman...

Страница 20: ...move the pot stands burner caps and burner bodies 1 Insert the socket into the central tube of the burner so that it locates over the brass gas jet at the bottom of the tube 2 Gently loosen the brass...

Страница 21: ...The lighting procedure has not been followed correctly Follow the correct lighting procedure The flame is yellow Pots and pans are stained The burners are dirty or wet Clean dry the burner components...

Страница 22: ...ed Wait until temperature goes down If the message persists then contact the customer care line FE Touch control temperature sensor may be damaged Wait until temperature goes down If the message persi...

Страница 23: ...vice defy co za Sub Saharan Africa Branches ZAMBIA SOUTHGATE INVESTMENTS LTD Plot 1606 Sheki Sheki Road P O Box 33681 Lusaka 10101 Zambia Tel 260 0211 242332 3 Fax 260 0211 242933 sgiservicecentre mic...

Страница 24: ...and attention in the use and maintenance of the appliance Abuse misuse in conflict with operating instructions connection to incorrect voltages and subjection to commercial use shall release the Comp...

Отзывы: