background image

DAC-515E Rev. C

3 Training Scenarios 

3.1  Available Scenarios

Six training scenarios (described below) are available for training exercises, and 

can be changed during training as desired.

The following scenarios are available: 

VF (Ventricular Fibrillation) that converts to a non-shockable rhythm 

(normal sinus rhythm) after the 1st shock. This scenario is based on 

the American Heart Association AED training scenario and allows for a 

quick overview and demonstration of AED operation.
Non-shockable rhythm throughout. 
Bad pads indication until the pads are disconnected and then re-

connected (simulating replacement of the pads), followed by VF that 

converts after the 1st shock to a non-shockable rhythm (normal sinus 

rhythm). 
VF that converts on the 2nd shock to a non-shockable rhythm (normal 

sinus rhythm).
Non-converting persistent VF.
Pads not applied to the patient. This scenario is recommended as the 

Default Scenario when using the Remote Control. The AED will prompt 

the student to apply pads to the patient dummy, and the instructor can 

then manually select rhythm simulations (such as NSR and VF) or any 

one of the above training scenarios using the Remote Control.

1.

2.
3.

4.

5.
6.

Note: 

When the AED Trainer is turned on, it will power up in the Default 

Scenario, not in the last-used scenario (see section 3.3 for instructions on setting 

the Default Scenario).

Note: 

Training scenarios 1-5 assume that pads have already been applied to 

the patient if pads are connected to the AED when the AED is turned on. For 

properly sequenced exercises using these training scenarios, the student should 

either apply the pads to the patient before turning the unit on, or turn the unit 

on with pads disconnected, apply the pads to the patient, and then connect the 

pads to the AED.

3.2  The Default Training Scenario

When a AED Trainer is first turned on, it operates in the “Default Training 

Scenario”.  The Default Training Scenario can be changed to any of the six available 

training scenarios.

Note:

  New Standalone AED Trainers and newly-configured DDU-100 AEDs are 

factory programmed to initially start with the Default Training Scenario set to 

scenario #1.

Содержание DDP-101TR

Страница 1: ...DAC 515E Rev C AED Training Equipment Standalone AED Trainer Training Battery Pack System User Manual Training Software V2 2...

Страница 2: ...rwise noted Limited Warranty The information in the Defibtech AED User Manual does not constitute any warranty as to the Defibtech AED or any related products The Limited Warranty shipped with Defibte...

Страница 3: ...1 Configuring a Defibtech DDU 100 series AED as a Trainer 3 3 Training Scenarios 4 3 1 Available Scenarios 4 3 2 The Default Training Scenario 4 3 3 Programming the Default Scenario 5 3 3 1 Programmin...

Страница 4: ...e patients A Remote Control is provided with the Standalone AED Trainer which allows the instructor to control training exercises and AED functions from a distance The Training Battery Pack System is...

Страница 5: ...will blink red and a warning chirp will be generated to warn the user that the AED is not capable of operating as a rescue de brillator 2 1 2 DTR 4XX series Remote Control The DTR 4XX series Remote C...

Страница 6: ...supplied with both system configurations Training Software Card DTR 3XX series supplied with both system configurations Training Pads use is optional Remote Control DTR 4XX series use is optional 2 3...

Страница 7: ...he student to apply pads to the patient dummy and the instructor can then manually select rhythm simulations such as NSR and VF or any one of the above training scenarios using the Remote Control 1 2...

Страница 8: ...g for the numbers to be announced in order to advance more quickly Turn the AED off The AED will now operate in the chosen training scenario until the Default Scenario is reprogrammed 3 3 2 Programmin...

Страница 9: ...ining dummy VFIB simulates Ventricular Fibrillation typically used once pads have been applied to the training dummy MOTION simulates a cardiac rhythm corrupted with excessive motion artifacts typical...

Страница 10: ...ill respond to this sequence regardless of name assignment 5 1 Assigning Unique Names to AEDs To program up to four AEDs with unique names use the following procedure Start with all the AEDs off Power...

Страница 11: ...and Electronic Equipment EEE may contain polluting components and hazardous substances which accumulation could pose serious risk for the environment and human health That s why local Administrations...

Страница 12: ...nds Tel 31 70 345 8570 Fax 31 70 346 7299 Patents pending This product and its accessories are manufactured and sold under one or more of the following United States patents D514 951 6 955 864 D499 18...

Отзывы: