DAC-515E Rev. C

2.2  Standalone AED Trainer 

WARNING: 

The Standalone AED Trainer

 

cannot

 

be used to defibrillate patients. 

The components required to operate the Standalone AED Trainer are: 

Standalone AED Trainer (DDU-100TR series).
Training Battery Pack (DBP-RCX series) - supplied with the Standalone 

AED Trainer.
Training Pads - 1 adult set (DDP-101TR) supplied.
Remote Control (DTR-4XX series) - supplied, but use is optional.

2.3  Training Battery Pack System  

The Defibtech Training Battery Pack System allows a standard Defibtech DDU-

100 Series AED to be converted to an AED training device. It is available in two 

configurations: one with a Remote Control and one without.

WARNING:

 While the Training Battery Pack is inserted in a DDU-100 series AED, 

the AED 

cannot 

be used to perform a rescue.  Replacing the Training Battery Pack 

with a rescue battery pack will immediately allow the AED to be used to perform 

a rescue. 

The components required to operate a DDU-100 series AED in training mode are: 

DDU-100 series AED.
Training Battery Pack (DBP-RCX series) - supplied with both system 

configurations.
Training Software Card (DTR-3XX series) - supplied with both system 

configurations.
Training Pads - use is optional
Remote Control (DTR-4XX series) - use is optional. 

2.3.1   Configuring a Defibtech DDU-100 series AED as a Trainer

Remove the rescue battery pack from the DDU-100 AED.
Insert the DTR-3XX series Training Software Card into the slot directly 

above the battery pack opening (label side up, notched end towards unit).
Insert the Training Battery Pack until it latches into place. 

The AED will now operate only in training mode. 

WARNING:

 While the Training Battery Pack is inserted in a DDU-100 series AED, 

the AED 

cannot 

be used to perform a rescue.  Replacing the Training Battery Pack 

with a rescue battery pack will immediately allow the AED to be used to perform 

a rescue. 

 

Note: 

The AED will announce “Training Mode” each time it is turned on. This will 

indicate that it cannot be used to defibrillate a patient while the Training Battery 

Pack is inserted.

WARNING: 

Training Pads 

cannot

 

be used to rescue a patient. If Training Pads are 

connected to a non-training configured AED, the AED will say “Check Pads,” and 

the AED will report an error during the next automatic self-test.

 

1.
2.

3.
4.

1.
2.

3.

4.
5.

1.
2.

3.

Содержание DDP-101TR

Страница 1: ...DAC 515E Rev C AED Training Equipment Standalone AED Trainer Training Battery Pack System User Manual Training Software V2 2...

Страница 2: ...rwise noted Limited Warranty The information in the Defibtech AED User Manual does not constitute any warranty as to the Defibtech AED or any related products The Limited Warranty shipped with Defibte...

Страница 3: ...1 Configuring a Defibtech DDU 100 series AED as a Trainer 3 3 Training Scenarios 4 3 1 Available Scenarios 4 3 2 The Default Training Scenario 4 3 3 Programming the Default Scenario 5 3 3 1 Programmin...

Страница 4: ...e patients A Remote Control is provided with the Standalone AED Trainer which allows the instructor to control training exercises and AED functions from a distance The Training Battery Pack System is...

Страница 5: ...will blink red and a warning chirp will be generated to warn the user that the AED is not capable of operating as a rescue de brillator 2 1 2 DTR 4XX series Remote Control The DTR 4XX series Remote C...

Страница 6: ...supplied with both system configurations Training Software Card DTR 3XX series supplied with both system configurations Training Pads use is optional Remote Control DTR 4XX series use is optional 2 3...

Страница 7: ...he student to apply pads to the patient dummy and the instructor can then manually select rhythm simulations such as NSR and VF or any one of the above training scenarios using the Remote Control 1 2...

Страница 8: ...g for the numbers to be announced in order to advance more quickly Turn the AED off The AED will now operate in the chosen training scenario until the Default Scenario is reprogrammed 3 3 2 Programmin...

Страница 9: ...ining dummy VFIB simulates Ventricular Fibrillation typically used once pads have been applied to the training dummy MOTION simulates a cardiac rhythm corrupted with excessive motion artifacts typical...

Страница 10: ...ill respond to this sequence regardless of name assignment 5 1 Assigning Unique Names to AEDs To program up to four AEDs with unique names use the following procedure Start with all the AEDs off Power...

Страница 11: ...and Electronic Equipment EEE may contain polluting components and hazardous substances which accumulation could pose serious risk for the environment and human health That s why local Administrations...

Страница 12: ...nds Tel 31 70 345 8570 Fax 31 70 346 7299 Patents pending This product and its accessories are manufactured and sold under one or more of the following United States patents D514 951 6 955 864 D499 18...

Отзывы: