background image

DAC-515E Rev. C

2 Training Equipment Components & Preparation

Note: 

The following section 2.1 applies to both the Standalone AED Trainer 

and the Training Battery Pack System. After reviewing this section, please refer 

to either section 2.2 or section 2.3

 

as appropriate to your specific training 

equipment.

2.1  Common Components

2.1.1   DBP-RCX series Training Battery Pack

The rechargeable DBP-RCX series Training Battery Pack is a component of both 

the Standalone AED Trainer and the Training Battery Pack System.  
Before use, the Training Battery Pack should be charged using the supplied battery 

pack charger (DTR-2XX series). The battery will fully charge in 12-14 hours. 

Note: 

Avoid overcharging for longest battery life – when proper charging 

procedures are followed, the battery pack should have a life of approximately 200 

charge/discharge cycles.
The Training Battery Pack does not require a 9V battery. 

Note:

 If a Training Battery Pack is installed in an AED or AED Trainer with a 9V 

battery, the ASI indicator light in the upper right corner of the AED will blink red 

and a warning chirp will be generated to warn the user that the AED is not capable 

of operating as a rescue defibrillator. 

2.1.2   DTR-4XX series Remote Control

The DTR-4XX series Remote Control is supplied with the Standalone AED Trainer 

and is an optional component of the Training Battery Pack System.  
Use of the Remote Control during training exercises is optional when using either 

equipment option. 
The Remote Control requires two AAA batteries. Insert the batteries into the 

battery compartment in the back of the Remote Control. No other setup of the 

Remote Control is required. 

2.1.3  Training Pads 

One set of adult training pads (DDP-101TR) is supplied with the Standalone AED 

Trainer and are available separately for optional use with the Training Battery Pack 

System.
Training pads are available as complete sets (pads, wire, & connector assemblies) 

and as economical replacement pads in both adult and pediatric sizes. The 

replacement pads attach (with hook and loop fasteners) to the reusable wire & 

connector supplied with complete pad sets.

Part numbers for these pad options are: DDP-101TR (Complete adult pad set), 

DDP-105TR (5-pack adult replacement pads), DDP-201TR (Complete pediatric pad 

set), DDP-205TR (5-pack pediatric replacement pads).

Содержание DDP-101TR

Страница 1: ...DAC 515E Rev C AED Training Equipment Standalone AED Trainer Training Battery Pack System User Manual Training Software V2 2...

Страница 2: ...rwise noted Limited Warranty The information in the Defibtech AED User Manual does not constitute any warranty as to the Defibtech AED or any related products The Limited Warranty shipped with Defibte...

Страница 3: ...1 Configuring a Defibtech DDU 100 series AED as a Trainer 3 3 Training Scenarios 4 3 1 Available Scenarios 4 3 2 The Default Training Scenario 4 3 3 Programming the Default Scenario 5 3 3 1 Programmin...

Страница 4: ...e patients A Remote Control is provided with the Standalone AED Trainer which allows the instructor to control training exercises and AED functions from a distance The Training Battery Pack System is...

Страница 5: ...will blink red and a warning chirp will be generated to warn the user that the AED is not capable of operating as a rescue de brillator 2 1 2 DTR 4XX series Remote Control The DTR 4XX series Remote C...

Страница 6: ...supplied with both system configurations Training Software Card DTR 3XX series supplied with both system configurations Training Pads use is optional Remote Control DTR 4XX series use is optional 2 3...

Страница 7: ...he student to apply pads to the patient dummy and the instructor can then manually select rhythm simulations such as NSR and VF or any one of the above training scenarios using the Remote Control 1 2...

Страница 8: ...g for the numbers to be announced in order to advance more quickly Turn the AED off The AED will now operate in the chosen training scenario until the Default Scenario is reprogrammed 3 3 2 Programmin...

Страница 9: ...ining dummy VFIB simulates Ventricular Fibrillation typically used once pads have been applied to the training dummy MOTION simulates a cardiac rhythm corrupted with excessive motion artifacts typical...

Страница 10: ...ill respond to this sequence regardless of name assignment 5 1 Assigning Unique Names to AEDs To program up to four AEDs with unique names use the following procedure Start with all the AEDs off Power...

Страница 11: ...and Electronic Equipment EEE may contain polluting components and hazardous substances which accumulation could pose serious risk for the environment and human health That s why local Administrations...

Страница 12: ...nds Tel 31 70 345 8570 Fax 31 70 346 7299 Patents pending This product and its accessories are manufactured and sold under one or more of the following United States patents D514 951 6 955 864 D499 18...