background image

- 9 - 

 

6.

 

LOCATIONS TO AVOID 

NEAR THE COOKING AREA:

   Do  not  install  the  monitor  within  five  feet  of  cooking 

appliances.  CO may be generated in the cooking process and cause nuisance alarms. 
Also, cooking grease can build up on the monitor and cause monitor failure. 

WITHIN  FIVE  FEET  OF  A  FURNACE,  WATER  HEATER,  OR  SPACE  HEATER:  

These devices often spill out small amounts of CO when they first turn on. 

IN GARAGES: 

 Automobile exhaust contains CO and will activate alarm. 

IN DUSTY AREAS: 

 Dust can build up on monitor and prevent it from working properly. 

IN  CLEANING  SUPPLY  ROOMS: 

  Cleaning  chemicals  and  painting  supplies  may 

cause nuisance alarms. 

IN UTILITY OR BATH ROOMS: 

 Do not install the monitor inside or within three feet of 

a  room  with  a  bathtub,  shower,  spa  or  washer/dryer.    Excessive  moisture  may  cause 
nuisance alarms. 

IN  VERY  HOT  OR  COLD  AREAS:     

Do  not  install  monitor  on  any  exterior  wall  or  in 

areas which are below 40

o

F or above 100

o

F. 

IN  DEAD  AIR  SPACE:

      Do  not  install  monitor  within  one  foot  of  where  wall  meets 

ceiling or floor. 

IN  HAZARDOUS  LOCATIONS:

      This  monitor  is  not  suitable  for  installation  in  a 

hazardous location, as defined in the National Electrical Code. 

NEAR WIRELESS DEVICES:

  

Do  not  install  the  monitor  within  one  foot  of  wireless 

devices. Radio Frequencies (RF) may interfere with the CO monitor’s proper operation. 
 
 

7.  INSTALLATION INSTRUCTIONS 

Follow these steps in this order to install the monitor:

 

1. 

Review Section 5,

 

RECOMMENDED LOCATIONS OF MONITORS

 

2. 

Review

 Section 6, 

LOCATIONS TO AVOID

 

3.  Fasten the mounting plate to the wall at eye level. Slide monitor down onto mounting 

plate. The monitor will be automatically activated. 

4.  It is important that you use the mounting plate provided. If the mounting plate is not 

used,  you  must  slide  the  activation  switch  at  the  back  of  monitor  to  the  left  until  it 
meets the Stop, ON position, as in diagram (D). 

5.  Once  activated,  the  CO  monitor  should operate for  up to five  years  without  battery 

replacement. 

6.  Press  and  hold  test  button  until  monitor  starts  to  beep,  then  release.  The  monitor 

should beep 4 times, pause, then beep 4 times again. 

ALARM

 red LED should flash 

at the same time. 

7.  Secure  monitor  to  mounting  plate,  with  Phillips  head  screw  provided,  through  the 

mounting hole on top of monitor (a tamper-proof screw may be used if required). 

8.  Be sure that the monitor is not obstructed by bedding, furniture, drapes, etc. 

 

Содержание LL6070

Страница 1: ...for Residential Single and Multiple Station Carbon Monoxide CO Alarms does not permit UL Listed CO alarms to activate an alarm signal for CO levels below 30 PPM The Defender LL6070 is designed to provide added protection for the elderly and young children who may be more vulnerable to lower levels of CO and is not UL Listed This monitor is intended to supplement not replace a UL Listed CO alarm Ma...

Страница 2: ... the instructions in Section 13 for service CAUTION THIS MONITOR WILL ONLY INDICATE THE PRESENCE OF CARBON MONOXIDE GAS AT THE SENSOR CARBON MONOXIDE GAS MAY BE PRESENT IN OTHER AREAS THIS CARBON MONOXIDE MONITOR IS DESIGNED TO DETECT CARBON MONOXIDE GAS FROM ANY SOURCE OF COMBUSTION IT IS NOT DESIGNED TO DETECT SMOKE FIRE OR ANY OTHER GAS THIS DEVICE IS DESIGNED TO HELP PROTECT INDIVIDUALS FROM T...

Страница 3: ...only After cleaning confirm that the POWER green LED flashes once every 60 seconds see Operation in Section 8 and test the monitor by operating the TEST RESET MUTE button DO NOT PAINT ON OR NEAR THE MONITOR The paint will damage the sensor or block the vents and affect the monitor function DO NOT SPRAY AIR REFRESHENER CLEANING SUPPLIES OR INSECT KILLER ON OR NEAR THE MONITOR Certain kinds of aeros...

Страница 4: ... PPM Automatic Audible and Visual Alarm Signals at 15 PPM Manually Displays Peak CO Levels Detected of 5 to 500 PPM Manually Displays Duration of Peak CO Level Separate Memory and Test Buttons Separate Alarm Power and Service LED s Integrated Battery Activation Deactivation Switch Self Diagnostic Circuitry and Sensor Life Monitor Secure Lock Mounting System Three Year Limited Warranty for Monitor ...

Страница 5: ...49 PPM 5 minutes Displays CO level beeps 4 times every 5 seconds for 5 minutes then beeps 4 times every minute and ALARM red LED flashes in sync with beep 150 500 PPM 3 minutes Displays CO level above 500 PPM flashes 500 PPM beeps 4 times every 5 seconds for 5 minutes then beeps 4 times every 20 seconds and ALARM red LED flashes in sync with beep Audible Mute Duration 15 24 PPM Mute button silence...

Страница 6: ...s Display Resolution 1 PPM Display Accuracy 15 or 5 PPM whichever is greater 50 RH 72 F 5 Because CO sensors typically lose sensitivity over time it is recommended that this monitor be replaced every three years in order to maintain a display accuracy as close to specified as possible The accuracy of the display below 30 PPM is an estimate for the first year only The sensor and display accuracy ma...

Страница 7: ...s ability to combine with oxygen is lost As the COHb concentration rises people become nauseous unconscious and ultimately die see below WHAT ARE THE SYMPTOMS OF CARBON MONOXIDE POISONING Many people often confuse carbon monoxide poisoning with the flu the initial symptoms being very similar Different concentrations of CO over various lengths of time cause different symptoms The following symptoms...

Страница 8: ...e immediate area of the bedrooms If more than one sleeping area exists locate additional alarms near each sleeping area 2 Install an alarm inside every room where someone sleeps with the door closed The closed door may prevent the alarm from waking the sleeper 3 Install a monitor inside every bedroom that is occupied by someone who may be hypersensitive to CO such as the elderly children or pregna...

Страница 9: ... installation in a hazardous location as defined in the National Electrical Code NEAR WIRELESS DEVICES Do not install the monitor within one foot of wireless devices Radio Frequencies RF may interfere with the CO monitor s proper operation 7 INSTALLATION INSTRUCTIONS Follow these steps in this order to install the monitor 1 Review Section 5 RECOMMENDED LOCATIONS OF MONITORS 2 Review Section 6 LOCA...

Страница 10: ...op and END OF LIFE signals are initiated STOP STOP slide to Stop To activate CO Monitor slide the monitor down onto mounting plate or slide to left to permanently deactivate CO Monitor when If the activation switch is not set to ON position as in diagram D the mounting hole at top of monitor will be blocked and the CO monitor will not be activated The model LL6070 is a sealed lithium battery power...

Страница 11: ... See Section 13 for handling an End of Life signal ALARM CONDITION When the batteries are active and CO gas is detected at a level and duration specified in Section 3 the horn will sound and ALARM red LED will light The alarm signal will sound 4 short beeps every minute for CO levels detected between 15 24 PPM or every 5 seconds if over 24 PPM The ALARM red LED will flash in sync with the beeping ...

Страница 12: ...feature is disabled at CO levels of 100 PPM or more See Section 10 WHAT TO DO WHEN THE ALARM SOUNDS To mute the audible horn during a low battery signal condition press the TEST RESET MUTE button The POWER green LED will blink for 5 seconds monitor will display at the same time and horn will be temporarily silenced for 24 hours The LCD will continuously display low battery signal symbol and curren...

Страница 13: ...ified during this inspection have the equipment serviced immediately Note any combustion equipment not inspected by the technician and consult the manufacturers instructions or contact the manufacturers directly for more information about CO safety and this equipment Make sure that motor vehicles are not and have not been operating in an attached garage or adjacent to the residence or facility MAN...

Страница 14: ... instructions 11 LIMITATIONS OF CARBON MONOXIDE MONITORS Carbon monoxide monitors respond to the presence of CO They do not detect smoke If the alarm does activate follow instructions in Section 10 WHAT TO DO WHEN THE ALARM SOUNDS Carbon monoxide monitors are devices that can provide an early warning of the presence of CO gas at a reasonable cost However monitors have sensing limitations and may n...

Страница 15: ...l has been activated See below procedures to remove and deactivate the monitor and discharge the batteries The monitor can be disposed of using the same method for disposing of discharged batteries Should the low battery voltage signal occur in less than five years after initial activation the battery power capacity may be low because of long term storage prior to installation exposure to low or h...

Страница 16: ...D OF LIFE signals are initiated STOP STOP slide to Stop To activate CO Monitor slide the monitor down onto mounting plate or slide to left to permanently deactivate CO Monitor when STOP slide to Stop To activate CO Monitor slide the monitor down onto mounting plate or E Monitor is activated and ON when switch is at STOP and mounting hole is open ON DEACTIVATE Lift up Stop and END OF LIFE signals a...

Страница 17: ...rrent CO level detected ALARM signals are same as CO gas alarm condition and POWER green LED blinks once when testing complete Beeps 4 times pauses for 5 seconds then beeps 4 times again Display Memory Displays highest CO level detected and duration of peak CO level Each readout lasts 5 seconds POWER green LED blinks once when CO memory display is completed Silent Clear Peak Memory Displays POWER ...

Страница 18: ...urer or an authorized service center Further the warranty does not cover acts of God such as fire flood earthquakes hurricanes and tornadoes The manufacturer shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty Except to the extent prohibited by applicable law any implied warranty of merchantability or fitness for a particular purp...

Отзывы: