![Defender LL6070 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/defender/ll6070/ll6070_owners-manual_2463531006.webp)
- 6 -
Sensor Type:
Electrochemical
Operating Temperature and Humidity:
40
o
F to 100
o
F @ 10% to 95% RH
Audible Signal:
Buzzer Horn Sounds 85 dB at 10 feet
Visual Signals:
•
POWER
green LED Indicates Power On
•
ALARM
red LED Indicates CO Alert or Alarm
•
SERVICE
red LED Indicates Service Required
Detection Frequency:
Samples for CO every 5 seconds
LCD Digital Display:
•
Automatically Displays Current CO Level Detected from 5 to 500 PPM
•
Manually Displays Highest CO Level Detected from 5 to 500 PPM
•
Manually Displays Duration of Peak CO Level from 0 to 999 minutes
•
Display Resolution 1 PPM
•
Display Accuracy ±15% or 5 PPM, whichever is greater, @ 50% RH, 72°F ±5°
•
Because CO sensors typically lose sensitivity over time, it is recommended that
this monitor be replaced every three years in order to maintain a display
accuracy as close to specified as possible. The accuracy of the display below 30
PPM is an estimate for the first year only.
•
The sensor and display accuracy may be affected by environmental conditions
and other circumstances beyond manufacturer's control.
Sensor Life Monitor
Activates sensor expiration signal after five years of operation
Factory Sealed Lithium Batteries
Two non-removable, non-replaceable lithium batteries for up to five years of
operation under normal conditions
Electrical Rating:
6VDC